SUN2000 Smart PV Optimizer
User Manual

2.4 Configuration Principles

The optimizer models supported by different inverters may vary, and different
optimizers may be configured for the same inverter. Select the optimizer model as
required.
Configuration Principles
The number of optimizers supported in a PV string, the upper limit of the string
power, and requirements for connecting PV strings in parallel vary according to the
inverter model. The configuration principles for different inverter models are as
follows:
Table 2-1 SUN2000-600W-P/SUN2000-450W-P2 configuration principles
Supported Inverter Models
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
SUN2000-3/4/5/6/8/10KTL-M1
SUN2000-8/10/12/15/17/20KTL-M2
SUN2000-29.9/30/36/40KTL-M3
SUN2000-20KTL-M3 (Brazil and
Japan)
SUN2000-4.95KTL-JPL1
SUN2000-4.95KTL-NHL2
Table 2-2 SUN2000-450W-P configuration principles
Supported Inverter Models
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
SUN2000-3/4/5/6/8/10KTL-M1
SUN2000-8/10/12/15/17/20KTL-M2
Issue 03 (2022-09-20)
NO TE
If two strings are connected in parallel to the inverter under the same MPPT circuit, the
restrictions for configuring optimizers are as follows:
● The PV strings connecting to the same MPPT should contain the same number and
model of PV modules and optimizers.
● All PV modules in the two strings must have the same orientation and tilt angle.
You are advised to use long strings instead of Y-shaped terminals.
Number of Optimizers
Supported in the String
4 to 25
6 to 35
6 to 35
6 to 25
6 to 25
4 to 25
4 to 25
Copyright © Huawei Digital Power Technologies Co., Ltd.
Number of Optimizers
Supported in the String
4 to 25
6 to 35
6 to 35
2 Product Introduction
String Power Upper
Limit
6 kW
10 kW
12 kW
12 kW
8 kW
6 kW
6 kW
String Power
Upper Limit
5 kW
10 kW
10 kW
8