Pvbs Main Spools - Danfoss PVG 16 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

62 |
©
Danfoss | December 2018
The main spools (PVBS) determine the flow out of the work section or the pressure build up and are
based on a generic platform with a wide selection of additional features, enabling you to tailor the PVBS
to suit the demands of any hydraulic system and any function.
The PVBS main spool can be activated in three different ways:
Mechanically by a PVM lever
Electrically by a PVE/PVHC actuator
Hydraulically by a PVH actuator
PVBS main spool
PVBS main spool dimensions
110 [4.33]
Weight: 0.16 kg [0.35 lb]
General features
4-way, positions
Optional 4-way, 4 positions with the right PVM
Flow control AB
Dead band 1.2mm [0.047 in]
PVBS Technical Parameters
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
46 [1.81]
14.8 [0.59]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
Maximum
90° [194°F]
2
2
/s [65 to 347 SUS]
460 mm
/s [2128 SUS]
BC00000211en-000901