Pveo Technical Data - Danfoss PVG 16 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Technical Information
PVG 16 Proportional Valve Group
PVG 16 Actuation
©
Danfoss | December 2018

PVEO Technical Data

Control Specifications
Description
Type
Supply Voltage (U
)
Range
DC
Max. ripple
Current Consumption
Typical
Pilot pressure
Minimum
10.0 bar [145 psi]
Fluid consumption
Neutral/Locked position
0.4 l/min [0.11 US gal/min]
Technical specification
Parameter
Fluid viscosity
Fluid cleanliness
Storage temperature
Operating temperature
LED characteristic
Color
Green constant
Part numbers for PVEO and PVEO-CI
Part number
Type
PVEO
11106793
PVEO
11106794
PVEO-CI
11124002
PVEO-CI
11149443
12 V
± 10%
DC
11 to 15 V
5%
320 mA
Nominal
13.5 bar [196 psi]
Actuating
0.6 l/min [0.16 US gal/min]
Minimum
Recommended range
2
4 mm
/s [39 SUS]
12 to 75 mm
18/16/13 (according to ISO 4406)
Ambient: -50 to 90°C [-58 to 194°F]
Ambient: -30 to 60°C [-22 to 140°F]
LED characteristic
Connector
Protection Class
1x4 DEUTSCH
IP 65
1x4 DEUTSCH
IP 65
1x4 DEUTSCH
IP 67
1x4 DEUTSCH
IP 67
24 V
± 10%
DC
12 to 30 V
DC
DC
5%
160 mA
Maximum
15.0 bar [218 psi]
Maximum
2
/s [65 to 347 SUS]
460 mm
Description
Power ON
Voltage
Interface
12 V
DC
24 V
DC
J1939/ISObus
CANopen
BC00000211en-000901 | 79
2
/s [2128 SUS]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvg 16 pvpPvg 16 pvsPvg 16 pvh/coversPvg 16 pvhcPvg 16 pvasPvg 16 pve ... Show all

Table of Contents