MAKING MODERN LIVING POSSIBLE Service Manual PVG 100 Proportional Valves powersolutions.danfoss.com...
Page 2
Service Manual PVG 100 Proportional Valves Revision history Table of revisions Date Changed October 2014 Danfoss layout June 2009 First edition 11048807 • Rev BA • October 2014...
Personal safety..................................... 6 Hazardous material..................................6 Acronyms ......................................7 Operation PVG 100 Group with Open Center PVPF..........................8 PVG 100 Group with Closed Center PVPV..........................8 PVG 100 Sectional Drawing................................9 PVPC Plug for External Pilot Oil Supply..........................10 PVPC with Check Valve for Open Center PVP.........................10 PVPC without Check Valve for Open Center PVP......................10...
Page 4
Service Manual PVG 100 Proportional Valves Contents PVB Pilot Check Valve .................................. 35 PVEH, PVES, Electrical Actuators............................... 36 Troubleshooting Considerations............................36 PVEO On/Off Electrical Actuator...............................37 PVPC Plug for External Pilot Control..........................38 PVMR Friction Module................................39 11048807 • Rev BA • October 2014...
Introduction Overview This manual includes information for servicing PVG 100 valves. It includes a description of the units and their individual components, troubleshooting information, and minor repair procedures. Performing minor repairs may require removal from the vehicle/machine. Thoroughly clean the unit before beginning maintenance, or repair activities.
Service Manual PVG 100 Proportional Valves Introduction For repair, place the unit in a stable position with the shaft pointing downward. Secure the motor while removing and torquing controls, and valves.Always consider safety precautions before beginning a service procedure. Protect yourself and others from injury. Take the following general precautions whenever servicing a hydraulic system.
Service Manual PVG 100 Proportional Valves Introduction Acronyms This table provides a definition of commonly used terms. P = Proportional V = Valve PVP/PVPF Pump side module, Open center PVPV Pump side module, Closed center Basic module PVLA Anti-cavitation valve...
PVG 100 Proportional Valves Operation PVG 100 Group with Open Center PVPF When the pump is started and the main spools in the individual basic modules are in the neutral position, oil flows from the pump, through connection P, across the pressure matching spool to tank. The oil flow led across the pressure matching spool determines the pump pressure (stand-by pressure).
Service Manual PVG 100 Proportional Valves Operation PVG 100 Sectional Drawing Logic cartridge for POC LS relief valve Pressure compensator LS connection 10. Shock and suction valve, PVLP Priority spool for CF 11. Main spool, PVBS LS connection for steering unit 12.
PVPC with Check Valve for Open Center PVP PVPC, with check valve, is used in systems where it is necessary to operate the PVG 100 valve by means of the electrical remote control without pump flow. When the external solenoid valve is opened, oil from the pressure side of the cylinder is fed via the PVPC through the pressure reducing valve to act as the pilot supply for the electrical actuators.
Service Manual PVG 100 Proportional Valves Operation Friction detent PVMR Friction Detent The friction detent PVMR allows the directional spool to be held in any position, resulting in infinitely variable, pressure compensated flow. The spool position will be held indefinitely without the necessity of holding the mechanical lever.
The coil on the valve must be energized for pilot oil to be available in the valve stack. This safety feature vents all hydraulic controls dependant on the PVG 100 pilot supply to the TØ gallery, thus reducing the possibility of accidental activation of a hydraulic work function.
Service Manual PVG 100 Proportional Valves Operation PVPE Electrical Full Flow Unloading Valve 350 bar Max. operation pressure [5085 psi] 1.2 bar Max. pressure drop a an flow of 0.20 l/min. [0.053 US gal/min] [17 psi] 30 to 60°C Recommended temperature [86 to 140°F]...
Confirm that valve is built properly according to the specification sheet. If necessary, install a lever to the valve to verify proper mechanical function. Refer to PVG 100 Technical Information Manual 520L0720 for valve configuration information. Refer to PVG 100 Parts Manual 520L0888 for part numbers.
Page 15
Service Manual PVG 100 Proportional Valves System Troubleshooting Our service manuals give full guidance on use of special tools. Troubleshooting flow chart Problem? Problem? Problem? Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic Electrical...
Excessive internal leakage may overheat the Install loop flushing defeat option and monitor system. case flow. If case flow is excessive, motor may require major repair. Contact Danfoss Service. Shock valves Swap and see if problem follows Replace valves Solenoid actuation...
Service Manual PVG 100 Proportional Valves System Troubleshooting Main Valve Spool Moves without Oil Passing to Cylinder/Motor Cause Check Corrective action Insufficient oil supply to valve Check the pump per manufacturers procedure Repair or replace pump per manufacturers procedure Optional pressure compensator in valve section...
Service Manual PVG 100 Proportional Valves System Troubleshooting Cause Check Corrective action Contamination in the hydraulic oil Take oil samples to confirm Flush hydraulic system. Fill with clean filtered oil. Cylinder/Motor Responds Slowly to Remote Electrical or Hydraulic Controller Cause...
Service Manual PVG 100 Proportional Valves System Troubleshooting Cause Check Corrective action Leaking or burst supply hose Inspect lines to valve stack Repair or replace damaged hose Relief valve malfunction Check for contamination and operation of relief Repair or replace relief valve...
Service Manual PVG 100 Proportional Valves System Troubleshooting Cause Check Corrective action Main spool position feedback transducer signal Test oil for contamination and or water content If oil contamination is too high, flush hydraulic incorrect system or replace oil if necessary. If problem...
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Open Center Pressure Relief Valve Description: Adjustable relief valve. Adjustment range 50 Bar [700 PSI] to 350 Bar [5000 PSI]. Location: The relief is in all PVP Inlet modules Function: Pilots the unloading valve to open when the load exceeda a set pressure.
Page 22
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Failure mode Cause Corrective action Main spools are slow, driven by PVE 13 Bar [190 Contamination Disassemble and clean PSI] pilot system Pump pressure too low - below 9 Bar [130 PSI]...
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting 13 mm 85 Nm [750 lbf•in] P107 921E Pressure Gauge Connection Description: Port to install a pressure gauge to check pressure relief valve setting to valve specification. Location: On inlet cover to valve stack.
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Location: PVP (inlet) module. Function: Provide a signal to the variable pump controller to create a pressure differential to have the pump come on stroke for a closed center system.
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Location: PVP/PVB Modules. Function: Directs the highest load pressure to either OC or CC pump control to satisfy the operating valve section. Failure mode Cause Corrective action No pump pressure developed in one or more LS passages blocked or restricted Disassemble valve.
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Failure mode Cause Corrective action Valve sections will not build pressure Worn shuttle disc Replace complete module (seat is pressed into module) Normally it will be one section, but not all...
Page 28
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Serviceability: Main spool is serviceable depending on failure mode. 1. Remove manual actuator (not shown) using a 5 mm internal hex wrench to remove the four mounting screws. Pull the spool out of the valve body.
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Failure mode Cause Corrective action Will not build pressure in A or B port Valve may be damaged and not able to seal Replace with correct part number per valve...
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Adjusting screws for ports A and B For standard mount, top adjusting screw is B and bottom adjusting screw is A PVM Module Description: Manual control lever. Location: Mounted on either end of the PVB main spool.
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting PVM module O-rings Seal Screw (x4) 5 mm 8 Nm [70 lbf•in] P107 848 PVT/PVTI Module Description: End cover. Location: Mounted on the last PVT of the valve stack. Function: Serves as blanking cover and drain for LS circuit.
PVLA 13 mm P107 849 40 Nm [354 lbf•in] For specifications and operating parameters on PVG 100 valves, refer to PVG 100 Technical Information Manual 520L0720. PVAS Module Description: Tie rod kit. Location: Through the valve stack. Function: Holds the stack together.
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting 10 mm 17 mm 38-42 Nm 38-42 Nm [28-31 lbf•ft ] [28-31 lbf•ft ] Nut for PVTI Nut for PVT PVTI P107 850 PVPP Pilot Shut Off Valve Description: Optional two way position solenoid normally closed...
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Failure mode Cause Corrective action Works in one direction (Assuming that the No control voltage from the electrical controller Ensure voltage from the electrical controller manual control lever and the main spool move...
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting Location: On the end of the main spool of the PVB. Function: Convert an electrical command to move the main spool to a set position. Failure mode Cause Corrective action...
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting PVPC plug for external pilot Check valve P107 958E PVMR Friction Module Description: Mechanical friction hold. Location: Mounted on main spool in the PVB. Function: Infinite mechanical positioning of the main spool.
Page 40
Service Manual PVG 100 Proportional Valves PVG 100 Component Troubleshooting PVMR module Plug 36 mm 15 Nm [133 lbf•in] Plug (x3) 11 mm Mechanical detent 4 Nm [35 lbf•in] Screw (x4) 5 mm 8 Nm [71 lbf•in] P107 811E 11048807 • Rev BA • October 2014...
Page 41
Service Manual PVG 100 Proportional Valves 11048807 • Rev BA • October 2014...
Page 42
Service Manual PVG 100 Proportional Valves 11048807 • Rev BA • October 2014...
Page 43
Service Manual PVG 100 Proportional Valves 11048807 • Rev BA • October 2014...
Page 44
Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
Need help?
Do you have a question about the PVG 100 and is the answer not in the manual?
Questions and answers