Pvbs, Main Mpools For Flow Control (Standard); Pvbs, Main Spools For Flow Control (With Linear Characteristic) - Danfoss PVG 100 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
PVG 100 function

PVBS, main mpools for flow control (standard)

PVBS, main spools for flow control (with linear characteristic)

18
PVG 100 Proportional Valve Group
P → A → F (Push-in)
With post-compensated valves, the A and B work port flow will depend on the pressure drop across the
main spool PVBS.
In open center systems, this pressure drop (standby-pressure) is determined by the volume of fixed pump
flow led to tank across the pressure adjusting spool in the inlet PVPF and the pressure adjusting spool
bias spring pressure. Since the pressure drop varies with pump flow volume led to tank, the A and B work
port flow will vary.
In closed center systems, the pressure drop across the main spool equals the standby setting of the
pump, measured at the P-port of the valve. The A and B work port flow will remain unchanged as long as
the standby is unchanged.
PVBS main spools with linear characteristic deliver a higher flow gain directly proportional to the linear
spool travel beyond the dead band.