Compensated Pvb With Ls A/B - Danfoss PVG 16 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Technical Information
PVG 16 Proportional Valve Group
PVB Basic Modules

Compensated PVB with LS A/B

46 |
©
Danfoss | December 2018
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independency on the load pressure of other functions used
simultaneously. The integrated LS
A/B-ports individually.
The compensated PVB with LS
Integrated LS shuttle network
Integrated compensator
Compensated PVB with LS A/B schematic
T
P
LX
1
0
2
Technical specification for A/B-port
Max. continuous pressure
350 bar [5076 psi]
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
relief valve is used to limit the maximum work port build-up on the
A/B
features:
A/B
T0
Pp
A
B
Max. intermittent pressure
420 bar [6090 psi]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
Max. rated flow
60 l/min [15 US gal/min]
Maximum
90° [194°F]
2
2
/s [65 to 347 SUS]
460 mm
/s [2128 SUS]
BC00000211en-000901

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvg 16 pvpPvg 16 pvsPvg 16 pvh/coversPvg 16 pvhcPvg 16 pvasPvg 16 pve ... Show all

Table of Contents