Open/Closed Center Pvpm - Danfoss PVG 16 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Technical Information
PVG 16 Proportional Valve Group
PVP Inlet Modules

Open/Closed center PVPM

32 |
©
Danfoss | December 2018
The Open Center/Closed Center PVPM mid-inlet acts as a simple manifold and is intended for use with
fixed or variable displacement pumps. The PVPM features no logic other than a PVLP shock/anti-
cavitation valve facility for pressure peak protection and anti-cavitation prevention.
The PVPM module must be configured together with an Open Center PVP module for fixed
displacement pumps and for variable displacement pumps can be configured together with a PVSI
start plate or a Closed Center PVP/PVPV module.
The Open center/closed center PVPM features:
Integrated shock/anti-cavitation valve facility (PVLP)
Threaded ports for P/T
Pilot pressure and T0 lines through module
Hydraulic schematic
T
P
Technical specification for PVP
Max. P-port continuous
Max. P-port intermittent
350 [5076 psi]
400 bar [5800 psi]
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
Part numbers for Open Center/Closed Center PVPM
Part number
11093682
11093684
Max. T-port static/
dynamic
25/40 bar [365/580 psi]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
P-, T-port
1 5/16-12 UN
G1"
Max. rated flow
140 l/min [37 US gal/min]
2
/s [65 to 347 SUS]
460 mm
Mounting
5/16-18 UNC
M8
BC00000211en-000901
Maximum
90° [194°F]
2
/s [2128 SUS]
PVLP
Yes
Yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvg 16 pvpPvg 16 pvsPvg 16 pvh/coversPvg 16 pvhcPvg 16 pvasPvg 16 pve ... Show all