Technical Information
PVG 16 Proportional Valve Group
PVP Inlet Modules

Open/Closed center PVP with PPRV

©
Danfoss | December 2018
The Open Center/Closed Center PVP with integrated pilot pressure reduction valve (PPRV) is intended for
use with fixed or variable displacement pumps in applications where the application manufacturer does
not determine the pump type.
The modules allow an easy switch between Open Center and Closed Center configuration by means of an
external hexagon selector key. Variants also feature an LS boost functionality, increasing the LS pressure
to the pump LS regulator with a constant 6 bar, compensating for potential LS bleed-off and leakage.
The Open/closed center PVPV with PPRV features:
Integrated OC/CC selector
Integrated LS pressure relief valve
Threaded ports for P/T/LS and M measuring gauge
Integrated pilot pressure reducing valve (PPRV) for PVE or PVH/PVHC
Optional LS boost functionality
Hydraulic schematic
LS
M
T
OC
CC
P
Technical specification for PVP
Max. P-port continuous
Max. P-port intermittent
350 [5076 psi]
400 bar [5800 psi]
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
Max. T-port static/
dynamic
25/40 bar [365/580 psi]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
Max. rated flow
140 l/min [37 US gal/min]
Maximum
90° [194°F]
2
2
/s [65 to 347 SUS]
460 mm
/s [2128 SUS]
BC00000211en-000901 | 29