Mains Supply 3 X 380/400/415 V - Danfoss VLT 3000 Series Product Manual

Frequency converter
Hide thumbs Also See for VLT 3000 Series:
Table of Contents

Advertisement

Mains supply 3 x 380/400/415 V

Acc. to international VDE and UL/CSA requirements
Constant torque (CT):
Output current
Output
Typical shaft output
Quadratic torque (VT):
Output current
Output
Typical shaft output
Max. cable cross-section
Max. motor cable length
Output voltage
Output frequency
Rated motor voltage
Rated motor frequency
Thermal protection during operation
Switching on output
Ramp times
Max. input current
Max. cable cross-section
Max. pre-fuses
Supply voltage
Supply frequency
Power factor / cos. ϕ
Efficiency
Switching on input
Weight (kg)
Power loss
at max. load
Enclosure
Vibration test
Relative humidity
Ambient temperature
(to VDE 0160)
EMC standards
(See section "EMC test results") Immunity
1) Only semi-conductor fuses.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the
specifications.
24
VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
I
[A]
VLT,N
I
[A] (60 s)
VLT,MAX
S
[kVA]
VLT,N
S
[kVA] (60 s)
VLT,MAX
P
[kW]
VLT,N
I
[A]
VLT,N
S
[kVA]
VLT,N
P
[kW]
VLT,N
[mm
2
]
[m]
U
[%]
M
f
[Hz]
M
U
[V]
M,N
f
[Hz]
M,N
[s]
VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
const. load I
[A]
L,N
quad. load. I
[A]
L,N
[mm
2
]
[A] 16.0 16.0
[V]
[Hz]
1
times/min.
VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
IP 00
IP 20
IP 21
IP 54 11.0 11.0
CT [W]
VT [W]
[g]
[%]
[°C]
[°C]
Emission
®
MG.30.A7.02 - VLT
is a registered Danfoss trademark
2.8
4.1
5.6
10.0
13.0
3.5
6.5
9.0
16.0
20.8
2.0
2.9
4.0
7.2
9.3
2.5
4.6
6.4
11.5
15.0
1.1
1.5
2.2
4.0
5.5
2.8
4.1
5.6
13.0
16.0
2.0
2.9
4.0
9.3
11.5
1.1
1.5
2.2
5.5
7.5
2.5
2.5
2.5
2.5
2.5
300, with screened cables: 150 m
0-100, of mains voltage
0-120 or 0-500; programmable
380/400/415
50/60/87/100
Integrated thermal motor protection (electronic);
thermistor to DIN 44081
Unlimited (frequent switching on output may result in fault message)
0.1 - 3600
2.8
4.8
7.0
10.0
13.0
2.8
4.8
7.0
13.0
17.0
2.5
2.5
2.5
2.5
2.5
16.0
25.0
25.0
3 x 380/400/415 ±10% (VDE 0160)
50/60 Hz
0.9/1.0
0,96 at 100% load
2
7.4
7.4
7.4
12.0
14.0
-
-
-
-
8.0
8.0
8.0
13.0
15.0
11.0
14.0
15.0
60
100
130
195
200
60
100
130
280
300
VLT type 3002-08: IP 00 / IP 21 / IP 54
VLT type 3011-52: IP 20 / IP 54
0.7
VDE 0160 5.2.1.2.
-10→ +40
operation at full load
2)
-25→ +65/70,
in storage/transport
EN 55011, EN 55014, EN 61000-3-2
EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5, VDE 0160, ENV 50140, ENV 50141
Technical data
16.0 24.0
32.0 44.0 61.0
25.6 38.4
51.2 70.4 97.6 117.0
11.5 17.2
23.0 31.6 44.0
18.4 27.6
36.8 50.5 70.2
7.5 11.0
15.0 22.0 30.0
24.0 32.0
44.0 61.0 73.0
17.2 23.0
31.6 44.0 52.5
11.0 15.0
22.0 30.0 37.0
16.0 16.0
16.0 35.0 35.0
13.8 21.8
30.7 41.9 55.6
22.0 31.0
41.5 57.5 66.5
16.0 16.0
16.0 35.0 35.0
50.0 63.0
63.0 80.0 100
-
-
-
-
-
24.0 26.0
32.0 49.0 54.0
-
-
-
-
34.0 37.0
48.0 63.0 69.0
270
425
580
880 1390
425
580
880 1390 1875
-10→ +45/40 (CT/VT)
at full load
2)
-25→ +65/70,
in storage/transport
73.0
52.5
84.1
37.0
88.0
63.3
45.0
50.0
66.5
80.0
50.0
1)
125
1)
-
-
54.0
-
-
69.0
1875
2155