Technical Data, Mains Supply 3 X 380 - 480 V - Danfoss VLT 2800 Series Operating Instructions Manual

Hide thumbs Also See for VLT 2800 Series:
Table of Contents

Advertisement

Technical data, mains supply 3 x 380 - 480 V

According to international stan-
dards
Output current
(3 x 380-480V)
Output power (400 V)
Typical shaft output
Typical shaft output
Max. cable cross sec-
tion, motor
Input current
(3 x 380-480 V)
Max. cable cross sec-
tion, power
Max. pre-fuses
3)
Efficiency
Power loss at 100%
load
Weight
4
Enclosure
According to international stan-
dards
Output current
(3 x 380-480V)
Output power (400 V)
Typical shaft output
Typical shaft output
Max. cable cross sec-
tion, motor
Input current
(3 x 380-480 V)
Max. cable cross sec-
tion, power
Max. pre-fuses
3)
Efficiency
Power loss at 100%
load
Weight
4
Enclosure
1. American Wire Gauge. Max. cable cross sec-
tion is the largest cable cross section that can be
attached to the terminals. Always observe national
and local regulations.
2. Type gG pre-fuses must be used. If you want to
maintain UL/cUL you must use pre-fuses of the
type Bussmann KTN-R 200 V, KTS-R 500 V or
Ferraz Shawmut, type ATMR (max. 30A). The
fuses must be placed for protection in a circuit that
is capable of supplying a maximum of 100,000
amps RMS (symmetrical), 500 V maximum.
80
VLT
Type
2805
I
[A]
1.7
INV.
I
(60s) [A]
2.7
MAX
S
[KVA]
1.1
INV.
P
[kW]
0.55
M,N
P
[HP]
0.75
M,N
2
1)
[mm
/AWG]
4/10
I
[A]
1.6
L,N
I
(60s)[A]
2.6
L,MAX
2
1)
[mm
/AWG]
4/10
2)
[A]/UL
[A]
20/20
20/20
[%]
96
[W]
28
[kg]
2.1
type
IP 20
IP 20
Type
2840
2855
I
[A]
9.1
INV.
I
(60s) [A]
14.5
19.2
MAX
S
[KVA]
6.3
INV.
P
[kW]
4.0
M,N
P
[HP]
5.0
M,N
2
1)
[mm
/AWG]
4/10
4/10
I
[A]
8.1
10.6
L,N
I
(60s)[A]
13.0
17.0
L,MAX
2
1)
[mm
/AWG]
4/10
4/10
2)
[A]/UL
[A]
20/20
25/25
[%]
96
[W]
200
275
[kg]
3.7
type
IP20
IP20
3. Measured using a 25 m screened/armoured mo-
tor cable with a rated load and rated frequency.
4. IP20 is standard for VLT 2805-2875, whereas
NEMA 1 is an option.
MG.28.A5.02 - VLT is a registered Danfoss trade mark
®
2800 Series
2807
2811
2815
2.1
3.0
3.7
3.3
4.8
5.9
1.7
2.0
2.6
0.75
1.1
1.5
1.0
1.5
2.0
4/10
4/10
4/10
1.9
2.6
3.2
3.0
4.2
5.1
4/10
4/10
4/10
20/20
20/20
96
96
96
38
55
75
2.1
2.1
2.1
IP 20
IP 20
2875
2880
12
16
24
25.6
38.4
8.3
11.1
16.6
5.5
7.5
11.0
7.5
10.0
15.0
4/10
16/6
14.9
24.0
23.8
38.4
4/10
16/6
25/25
50/50
96
96
97
372
412
6.0
6.0
18.5
IP20
IP20/
NEMA 1
2822
2830
5.2
7.0
8.3
11.2
3.6
4.8
2.2
3.0
3.0
4.0
4/10
4/10
4.7
6.1
7.5
9.8
4/10
4/10
20/20
20/20
96
96
110
150
3.7
3.7
IP 20
IP 20
2881
2882
32.0
37.5
51.2
60.0
22.2
26.0
15.0
18.5
20.0
25.0
16/6
16/6
32.0
37.5
51.2
60
16/6
16/6
50/50
50/50
97
97
562
693
18.5
18.5
IP20/
IP20/
NEMA 1
NEMA 1