Mains supply 3 x 440/460/500 V
Acc. to international VDE and UL/CSA requirements
Constant torque (CT):
Output current
Output
Typical shaft output
Quadratic torque (VT):
Output current
Output
Typical shaft output
Max. cable cross-section
Max. motor cable length
Output voltage
Output frequency
Rated motor voltage
Rated motor frequency
Thermal protection during operation
Switching on output
Ramp times
Max.
input current
Max. cable cross-section
Max. pre-fuses
Supply voltage (VDE 0160)
Supply frequency
Power factor / cos. ϕ
Efficiency
Switching on input
Weight (kg)
Power loss at max. load
Enclosure
Vibration test
Relative humidity
Ambient temperature
(to VDE 0160)
Frequency converter protection
EMC standards
(See section "EMC test results")
1) Semi-conductor fuses.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the specifications.
26
VLT type
3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
I
[A]
VLT,N
I
[A] (60s)
VLT,MAX
S
[kVA]
VLT,N
S
[kVA] (60s)
VLT,MAX
P
[kW]
VLT,N
I
[A]
VLT,N
S
[kVA]
VLT,N
P
[kW]
VLT,N
[mm
2
]
[m]
U
[%]
M
f
[Hz]
M
U
[V]
M,N
f
[Hz]
M,N
[s]
VLT type
3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
const. load. [A]
quadratic load [A]
[mm
2
]
[A]
[V]
[Hz]
1
times/min.
VLT type
3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
IP 00
IP 20
IP 21
IP 54
CT [W]
VT [W]
[g]
[%]
[°C]
[°C]
Emission
Immunity
®
MG.30.A7.02 - VLT
is a registered Danfoss trademark
2.6
3.4
4.8
8.2
11.1
3.4
5.5
7.7
13.1
17.6
2.3
2.9
4.1
7.1
9.6
2.9
4.7
6.7
11.3
15.2
1.1
1.5
2.2
4.0
5.5
2.6
3.4
4.8
8.2
11.1
1.6
2.9
4.1
7.1
9.6
1.1
1.5
2.2
4.0
5.5
2.5
2.5
2.5
2.5
2.5
300, with screened cables: 150 m (3011-3052 in VT: 150 m and 40 m)
0-100, of mains voltage
0-120 eller 0-500, programmable
440/460/500
50/60/87/100
Integrated thermal motor protection (electronic); thermistor to DIN 44081
Unlimited (frequent switching on output may result in fault message)
0.1 – 3600
2.6
3.4
4.8
8.2
11.1
2.6
3.4
4.8
8.2
11.1
2.5
2.5
2.5
2.5
2.5
16.0
16.0
16.0
25.0
25.0
3 x 440/460/500 ±10% (VDE 0160)
50/60
0.9/1.0
0.96 at 100% load
2
7.4
7.4
7.4
12
-
-
-
-
8.0
8.0
8.0
13
11
11
11
14
60
100
130
160
200
60
100
130
160
200
VLT type 3002-08: IP 00 / IP 21 / IP 54
VLT type 3042-52: IP 20 / IP 54
0.7
VDE 0160 5.2.1.2.
-10→ +40
at full load
2)
-25→ +65/70
in storage/transport
Protection against earthing and short-circuiting
EN 55011, EN 55014
EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5, VDE 0160, ENV 50140, ENV 50141
Technical data
14.5
21.7 27.9 41.4 54.0
23.2
34.7 44.6 67.2 86.4 104.0
12.6
18.8 24.2 36.0 46.8
20.1
30.1 38.6 58.2
7.5
11.0 15.0 22.0 30.0
21.7
27.9 41.4 54.0 65.0
18.8
24.2 35.9 46.8 56.3
11.0
15.0 22.0 30.0 37.0
16.0
16.0 16.0 35.0 35.0
12.6
20.1 26.8 37.3 50.2
19.6
26.0 34.8 48.6 60.3
16.0
16.0 16.0 35.0 35.0
30.0
40.0 50.0 60.0 100.0
14
-
-
-
-
-
25
26
31
49
15
-
-
-
-
15
34
37
48
63
174
287
580
958 1125 1467
281
369
880 1133 1440 1888
VLT type 3011-52: IP 20 /IP54
-10→ +45/40(CT/VT)
at full load
2)
-25→ +65/70
in storage/transport
65.0
56.3
7.8
90.1
37.0
78.0
67.5
45.0
50.0
61.3
72.0
50.0
1)
125.0
1)
-
-
54
54
-
-
69
69