3.2.

Connecting the wastewater pump(s)

Caution: risk due to electrical current if a plug is opened without authorisation during operation, e.g. by a child!
The fastening nut for the plug must be tightened such that a child cannot open it..
Connect the wastewater pump(s) as follows:
• Connect the cable plug as shown in Fig. [7].
Tighten the nut to 3 Nm. The gap <32> between the nut
and the plug connection should be 3-4 mm (see Fig. [8])
Pump 1 = <30>
Pump 2 = <31> (Duo version only)
The cable for the pumps can be extended or shortened. Please see:
- 7.2, Control unit retrofits, special conditions
- 7.4.1, Shortening or extending the pump/sensor connection cable
ASSEMBLY
[7]
[8]
44/68
Aqualift Comfort
30
31
[6]
32
2018/06