Installation; General Installation Information; Connecting The Backwater Valve; Functional Check - Kessel Staufix Instructions For Installation, Operation And Maintenance

Backwater valve for installation in through pipes
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
4

Installation

4.1

General installation information

– Unless specified otherwise, the individual installation steps described are for the installation
type "Installation in a concrete slab". The same installation steps apply analogously for
installation in an exposed pipe.
– Make sure there is a sufficient gap to the wall or objects for maintenance work to be carried
out.
4.2

Connecting the backwater valve

(illustration shows installation in an exposed pipe)
• If necessary, fix the two connecting pieces inlet <3> and
outlet side <2> to the drain body <1> using the quick-
release closures <4> (see installation instructions for the
connecting pieces). Check for a firm and flush seat.
• Connect the backwater valve to the pipe system. For this,
make sure that
– the backwater valve is aligned vertically upwards with
the operating elements as shown
– the installation location corresponds to the direction of
flow <5>
• Make sure that the one-handed closure* <6> is closed.
* Drain bodies from DN 150 have two one-handed closures.
4.3

Functional check

2019/07
Installation
20 / 72
4
3
4
Ill. [4]
5
6
1
2
016-052