Xtreme Power Conversion M90S Series User & Installation Manual page 76

Online split-phase ups 6kva, 12kva, 18kva, 24kva models
Hide thumbs Also See for M90S Series:
Table of Contents

Advertisement

M90S-4S User's Manual
4) Others setting
Interface
Others:
Hot Standby: Disable
Audible Mute:
Disable
Language:
English
>>>
Others:
Bat Mute: Disable
Fault Mute:
Disable
Bypass Mute: Disable
>>>
Others: Redundancy:
Total Power: 02
Standard Mode: Enable
Factory Reset
<<<
Xtreme Power Conversion Corporation
Description
1. Hot standby(only available or effective on bypass mode and standby mode):
Enable: Hot standby function is enabled. It means that the current
UPS is set to be host of hot standby system, and it will automatically restart after AC
recovery even without battery connected.
Disable: Hot standby function is disabled. The UPS is running at
normal mode and can't restart without battery. The default setting is Disable.
2. Audible Mute(available or effective for all modes):
Enable: It is to mute the buzzer.
Disable: It is to enable the buzzer when UPS have alarms or UPS
is working in bypass mode or Battery mode. The default setting is Disable.
3. Language(available or effective for all mode):
English: All interface will show in English
4. Bat Mute(available or effective on all modes):
Enable: It is to mute the buzzer when UPS in Battery mode.
Disable: It is to enable the buzzer in Battery mode. The default setting is Disable.
5. Fault Mute(available or effective on all mode):
Enable: It is to mute the buzzer when UPS in Fault mode.
Disable: It is to enable the buzzer in Fault mode. The default setting is Disable.
00
6. Bypass Mute(available or effective on all mode):
Enable: It is to mute the buzzer when UPS in Bypass mode.
Disable: It is to enable the buzzer in Bypass mode. The default setting is Disable.
7. Redundancy (available or effective on all modes): The setting is quantity of re-
dundant UPS module. The setting range is 0~9. The
setting quantity must be less than the number of UPS modules in the
system. The default value is 0.
8. Total Power (available or effective on all mode): The parallel number we set in
system.
9.Standard Mode(only available or effective on bypass mode and standby mode):
Enable: It is a compatible mode for dynamo.
Disable: It is a normal mode. The default setting is Enable.
10. Factory Reset (only available or effective on bypass mode and standby mode):
Restore to factory default setting.
Uninterruptible Power Supply
Page 76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents