UNINTERRUPTIBLE POWER SUPPLY (UPS) 
 
 
 
 
S70 Line‐Interactive
Low Voltage Tower Models 
 
USER & INSTALLATION MANUAL 
 
 
             www.xpcc.com | © 2012 Xtreme Power Conversion Corporation. All rights reserved. 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for Xtreme Power Conversion S70 Line?Interactive

  • Page 1     UNINTERRUPTIBLE POWER SUPPLY (UPS)          S70 Line‐Interactive   Low Voltage Tower Models    USER & INSTALLATION MANUAL                               www.xpcc.com | © 2012 Xtreme Power Conversion Corporation. All rights reserved.   ...
  • Page 2: Package Contents

    S70 SERIES USERS MANUAL                                                                    V2  Package Contents  You should be receiving the following items inside the package:    UPS Unit    User Manual    Local Monitoring Software CD    USB cable  Product Introduction  Thank you for selecting this uninterruptible power supply (UPS). It  provides  you  with  protection  for  connected  equipment.  Please  read this manual before installing the S70‐Series UPS models S70‐ 500,  S70‐700,  S70‐1000,  S70‐1500,  and  S70‐2000  as  it  provides  important information that should be followed during installation  and  maintenance  of  the  UPS  and  batteries,  allowing  you  to  correctly ...
  • Page 3 S70 SERIES USERS MANUAL                                                                    V2  systems from poor quality utility power, complete loss of power,  or other associated problems.  Electrical  interference  exists  in  many  forms,  causing  problems  in  AC  power,  from  lightning,  power  company  accidents  and  radio  transmission  motors,  air  conditioners,  and  vending  machines.  Protection  of  sensitive  electrical  equipment  is  vital  to  protect  against  power  outages,  low  or  high  voltage  conditions,  slow  voltage ...
  • Page 4 S70 SERIES USERS MANUAL                                                                    V2   When AC input power returns, the UPS automatically  begins supplying the load with power through the AVR  circuit.   The charger circuit provides recharge for the batteries.            Xtreme Power Conversion® (XPC) Corporation                                 4 ...
  • Page 5 S70 SERIES USERS MANUAL                                                                    V2         Xtreme Power Conversion® (XPC) Corporation                                 5 ...
  • Page 6 S70 S SERIES USERS S MANUAL                                                                     V2    Inst tallation &  Initial Sta artup     Before in nstallation, i inspect the u unit and pac ckaging to  ke sure that n nothing insid de has been  damaged.  Plac cement & St torage    Insta all the UPS in n a protecte d area that i is free of exc cessive dust  and  has adequat te air flow. P Place the UP PS away from m other units s at  least t 7.8 in (20 c cm) to avoid ...
  • Page 7 S70 SERIES USERS MANUAL                                                                    V2  Connect UPS to Utility and Charging  Before  the  initial  use  of  the  UPS,  plug  the  UPS  input  cord  into  a  wall  outlet  and  turn  the  UPS  on  by  depressing  the  Power  switch  on the front of the UPS. For best results, the batteries in the UPS  should  be  charged  for  at  least  6  hours  before  use.  The  UPS  charges ...
  • Page 8: Important Safety Instructions

    S70 SERIES USERS MANUAL                                                                    V2  the UPS. To turn the UPS unit off, press the Power switch on the  front of the unit again.  Cold Start Function  When the UPS is off and there is not input utility power available,  it is still possible to cold start the UPS unit to power loads. Follow  the  instructions  for  Turning  UPS  ON  and  be  aware  that  you  will  see and hear the ON BATTERY ALARM.  IMPORTANT SAFETY INSTRUCTIONS:  (SAVE THESE INSTRUCTIONS)  CAUTION!  (UPS  having  Internal  Batteries):  Risk  of  electrical  shock  –  Hazardous  live  parts  inside  this  unit  are  energized  from  the  battery  supply even when the input AC power is disconnected. ...
  • Page 9 S70 SERIES USERS MANUAL                                                                    V2  Servicing of  batteries should  be  performed or supervised by  personnel  with  knowledge  of  batteries  and  the  required  precautions.  Keep  unauthorized personnel away from batteries.  The instructions contained within this safety manual are deemed  important and should be closely followed at all times during installation  and follow‐up maintenance of the UPS and batteries .             Xtreme Power Conversion® (XPC) Corporation                                 9 ...
  • Page 10: Troubleshooting

    S70 SERIES USERS MANUAL                                                                    V2  Troubleshooting   Condition  Visual Indicator  Alarm  Charge the UPS at least 6  Low battery  hours  Replace the battery with  No words display on  Battery fault  the same type of battery  front panel  The UPS is not  Press the Power Switch  turned on  on the front of the UPS  Alarm continuously  Remove some of the load  The UPS is  sounds when the AC  from the output of the  overloaded  input is normal   UPS  Remove some of the load  The UPS is  from the output of the  overloaded  UPS  Battery voltage is  Charge the UPS at least 8  When power fails,  too low  hours  backup time is shorter  Battery defect –  than expected    possibly due to high  environmental ...
  • Page 11: Specifications

    S70 SERIES USERS MANUAL                                                                    V2  Specifications  120V Model  S70-500 S70-700 S70-1000  S70-1500 S70-2000     Voltage 120VAC (81-145) Capacity VA 500VA 700VA 1000VA 1440VA 2000VA INPUT  (300W) (420W) (600W) (900W) (1200W) Frequency 60 Hz auto sensing Voltage 120VAC (108-132) Waveform Simulated sine wave OUTPUT  Frequency 60 ±...
  • Page 12: Indicators & Alarms

    S70 SERIES USERS MANUAL                                                                    V2  120V Model  S70-500 S70-700 S70-1000  S70-1500 S70-2000     Operating 32-104F (0-40ºC) Temperature Humidity 0%-90% ENVIRONMENT  Audible < 40dB Noise Altitude 11,500 ft (3500 m) above sea level AC Mode, Battery Mode, Load Level, Battery Level, Input LCD Display Voltage, Output Voltage, Overload, Fault, Low Battery Battery Mode Alarm sounds every 10 seconds Low Battery...
  • Page 13: Obtaining Service

    S70 SERIES USERS MANUAL                                                                    V2  Obtaining Service  If the UPS requires Service:   1. Use  the  TROUBLESHOOTING  section  in  this  manual  to  eliminate  obvious  causes.  2. Verify there are no circuit breakers tripped.  3. Call your dealer for assistance. If you cannot reach your dealer, or if they  cannot resolve the problem, call Xtreme Power Conversion Corp Technical  Support at 800.582.4524. Technical support inquiries can also be made at  support@xpcc.com. Please have the following information available BEFORE  calling the Technical Support Department:     a. Your name and address.   b. The serial number of the unit.  c. Where and when the unit was purchased.  d. All of the model information about your UPS.  e. Any information on the failure, including LED’s that may or may not be  illuminated.  f. A  description  of  the  protected  equipment,  including  model  numbers  if  possible. ...
  • Page 14 S70 SERIES USERS MANUAL                                                                    V2  XTREME POWER CONVERSION  (XPC) CORPORATION LIMITED WARRANTY  ® Xtreme  Power  Conversion  (XPC)  Corporation  warrants  Xtreme  Power  Conversion  equipment,  when  properly  applied  and  operated  within  specified  conditions,  against  faulty  materials  or  workmanship  (excluding  batteries)  for  a  period  of  three  years  for  S70‐Series  products  from  the  date  of  purchase.    XPC  Corporation  warrants  internal  batteries ...
  • Page 15 S70 SERIES USERS MANUAL                                                                    V2  XTREME POWER CONVERSION  LOAD PROTECTION POLICY  ® For Standard EPC 120, 208 and 240 Volt Products used in the United States and Canada  THIS POLICY IS NOT A WARRANTY. REFER TO THE XPC CORPORATION, INC. LIMITED  WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC  PRODUCT. THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT  AFFECT THE TERMS OF THE XPC LIMITED WARRANTY.  Definitions:    “Product” means an XPC Standard EPC 120, 208, or 240 Volt power protection device  that is used in the United States and Canada.  This policy does not include custom  manufactured products.    “Power Disturbance” means an AC power line transient (telephone line, local Area  Network or CATV transients, if applicable), spike or surge.    “Fair Market Value” of damaged Connected Equipment as determined by XPC shall be  the  lower  of  (a)  the  average  price  the  same  or  similar  items  are  being  sold  for  on  eBay, (b) the price list of Orion Blue Book (or if such price list is no longer published, a  published or announced price list reasonably selected by XPC), (c) the lowest price the  same  or  similar  items  can  be  purchased  for  in  the  United  States  or  (d)  the  total  amount ...
  • Page 16 S70 SERIES USERS MANUAL                                                                    V2    All Connected Equipment must be UL or CSA approved.    The  Product  must  be  plugged  into  a  properly  wired  and  grounded  outlet.  Use  of  input  surge  devices, extension cords, adapters, ground wires, or electrical connections not manufactured by  XPC voids the XPC Load Protection Policy. No other surge protection device may be connected to  the output sockets of the Product. The installation must comply with all applicable electrical and  safety codes set forth pursuant to the NEC.    The Product must have undeniable physical evidence of a Power Disturbance that directly and  proximately caused the damage;     The  Connected  Equipment  must  have  been  damaged  by  a  Power  Disturbance  on  a  properly  installed, grounded, and National Electric Code, ("NEC"), ...
  • Page 17 S70 SERIES USERS MANUAL                                                                    V2  THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND INJURY TO PROPERTY.  Submitting a Load Protection Policy Claim:    Any claim under the Load Protection Policy must be made within 10 days of the date of  alleged damage to the Connected Equipment.    Call  the  XPC  technical  support  department  at  1‐800‐  582‐4524  and  obtain  a  Load  Protection  Policy  Returned  Material  Authorization  (RMA)  number.  Have  information  on  all  applicable  insurance or other resources of recovery/payment that are available to the Initial Purchaser and  the  name  of  the  power  utility  supplier  for  the  location  of  the  Connected  Equipment.  XPC  will  forward ...
  • Page 18 S70 SERIES USERS MANUAL                                                                    V2                         For more information about Xtreme Power Conversion  Corporation products, services, or UPS Selector sizing,   please visit www.xpcc.com       Xtreme Power Conversion® (XPC) Corporation                                 18 ...

Table of Contents