Table of Contents

Advertisement

The 210 indicator allows several operational parameters to be reviewed and changed without
breaking the calibration seal. These operational parameters are:
To enable the Setup Review feature, with the indicator ON:
1. Press the  key. The indicator will respond by showing the FUnCt= (Function) prompt
and alternately flashing off and on (all ON, weighing unit off, then all OFF, weighing unit
ON) the annunciators.
2. Press the ZERO/REVIEW key. The display will change to the prompt for the selection of
power-up zeroing (PUO=).
3. Using the same procedure as described in the Setup and Calibration section of this
manual, make the required changes.
4. Press the  key to return to the previous prompt.
5. To exit Setup Review, press the ENTER key to step the remaining prompts OR at
anytime, cycle the power (press the ON/OFF key twice).
8200-M585-O1 Rev D  210 Installation & Technical

SETUP REVIEW

Power Up Zero Reset Enable/Disable
Time Format
Sleep Mode Feature Enable/Disable
Auto Shutoff Feature Enable/Disable
Serial Input / Output Configuration
Baud Rate
Parity
Number of Data Bits
Number of Stop Bits
Continuous Output Port 1
Continuous Output Format
Continuous Output Port 2
Continuous Output Format
Print Tab Settings
Printer Port Selection
Time
Date
Consecutive Number
Gross Weight
Tare Weight
Net Weight
Gross Weight Accumulator
Net Weight Accumulator
Count
Piece Weight
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents