The 204 allows several operational parameters to be reviewed and changed as necessary
without having to enter the setup and calibration mode. The parameters in the setup review
will be processed in the following sequence:
Disable battery charging (use Alkaline batteries), Enable battery charging
NiCAd=
(use Ni-Cad or NiMH) or Enable battery charging and Force charging of
discharged Ni-Cad or NiMH batteries.
PUO=
Enable or Disable automatic reset of weight display to zero on power up.
Disable or select number of minutes for automatic shutoff timer.
ASH=
Disable or select number of minutes of inactivity at zero for sleep mode.
SLP=
BAUd=
Select baud rate for serial I/O port.
PrtY=
Select serial port parity.
Prt=
Select the ticket format to be used when the PRINT key is pressed.
Enable or Disable the continuous output.
COnt=
EOP=
The Number of Ending Linefeeds Printed.
To Enter the Setup Review Mode
1. Turn the 204 off.
2. Press and hold the PRINT key and then press the ON/OFF key.
3. The display will then prompt with niCAd=, the selection to use Ni-Cad (NiMH) or
Alkaline batteries.
4. Refer to the instructions listed in the Setup and Calibration section of this manual for
information on how to change these parameters.