Setup Review - Cardinal Detecto 758C Owner's Manual

With body mass index features
Table of Contents

Advertisement

The 758C indicator allows several operational parameters to be reviewed and changed as
necessary without having to remove the calibration jumper J2 and enter the setup mode.
To Enter Setup Review
1. If indicator is on, press the ON/OFF key.
2. Press and hold the ZERO key and then press the ON/OFF key.
3. The indicator will perform a display test (turn on all digits), show the software version for
a few seconds and then change to show ruieW
4. Release the ZERO key.
5. The display will change to HirES = (prompt to enable High Resolution Mode feature).
6. Refer to instructions listed in Setup and Calibration section of manual for information on
how to change these parameters.
Parameters in Setup Review will be processed in the following sequence:
 HirES
Enable High Resolution
 Tra=
Select the number of scale divisions automatically zeroed on power up
 Allyn=
Select whether the indicator is interfaced to a Welch Allyn device
 Nin=
Set the minutes portion of the time
 HH=
Set the hours portion of the time
 Dd=
Set the day of the month
 Nn=
Set the month of the year
 Yy=
Set the year
 iD=
Enable or Disable ID number input feature
 iDbar=
Enable or Disable ID Scanner
 Htr=
Enable or Disable Digital Height Rod Port
 Bni=
Enable or Disable BMI calculation feature
 P220=
Select weight data format for P220 printer or P185 printer
 CrLF=
Set P185 Printer Mode (P185 Journal Mode or P185 Ticket Mode)
 EOP=
Set Number of End Of Print linefeeds printed
 bAUd=
Select baud rate for serial output
 PPORT
Select Serial or Ethernet or USB Device port for Data Port
 COnt!
Enable or Disable Serial Port Continuous Output
 COnt2
Enable or Disable Ethernet Port Continuous Output
 COnt3
Enable or Disable USB Device Port Continuous Output
 Btn=
Enable or Disable NET/GROSS, TARE and/or ID/HEIGHT keys
 niCAd
Select to use Ni-Cad (NiMH) or Alkaline batteries
 PUO=
Enable or Disable automatic reset of weight display to zero on power up
 ASH=
Disable or select number of minutes for automatic shutoff timer
 SLP=
Disable or select number of minutes of inactivity at zero for sleep mode
NOTE: If HirES= 1 (YES) is selected, the indicator will exit Setup Review and display
weight in High Resolution Weight mode. To return to Setup Review, repeat steps 1 to 4
above.