Setup Review - Cardinal 204 Operation Manual

Weight indicating instrument
Table of Contents

Advertisement

SETUP AND CALIBRATION, Cont.
Print Ticket Format
The display will now show Prt=. Press the ASTERISK key to view the current setting. If
acceptable, press the PRINT key to save it. Otherwise use the UNITS key to change the
selected print ticket format. Allowable values are:
0 = Default Format
Continuous Output
The display will now show COnt=. Press the ASTERISK key to view the current setting. If a 1
(1=YES) is displayed, the feature has been enabled and the 204 will send a continuous output
of weight data to the serial I/0 connector. If a 0 (0=NO) is displayed the data will only be
transmitted when the PRINT key is pressed or on receipt of an ENQ command from a
computer. Press the UNITS key to change between 1 (YES) and 0 (NO). Once the proper
setting is displayed, press the PRINT key to save the setting. Note: This setting may be
revised without having to enter the calibration mode.
End-Of-Print Line Feeds
The display will now show EoP=. At the end of a data transmission to a printer, the 204 can
send a number of line feed commands to space the paper in the printer to the desired position
for withdrawal or for the next print. Press the ASTERISK key to view the current setting. If the
setting shown is acceptable, press the PRINT key to save it. Otherwise, use the UNITS key to
select the desired number of line feeds (0 to 99). With the desired number displayed, press
the PRINT key to save the setting. NOTE: This setting may be revised without having to enter
the calibration mode.
Done
The indicator display will now show dOnE. The setup and calibration process has been
completed. Remove the power from the indicator and re-assemble for use.
The 204 allows several operational parameters to be reviewed and changed as necessary
without having to enter the setup and calibration mode. The parameters in the setup review
will be processed in the following sequence:
• NiCAd
Select to use Ni-Cad (NiMH) or Alkaline batteries
• PUO
Enable or Disable automatic reset of weight display to zero on power up
• ASH
Disable or select number of minutes for automatic shutoff timer
• SLP
Disable or select number of minutes of inactivity at zero for sleep mode
• BAUd
Select baud rate for serial I/O port.
• Prt
Select the ticket format to be used when the PRINT key is pressed.
• Cont
Enable or Disable the continuous output.
• EoP=
The Number of Ending Linefeeds Printed.
To enter the setup review mode, simply turn the 204 off then press and hold the PRINT key
then press the ON key. The display will then prompt with niCAd, the selection to use Ni-Cad
(NiMH) or Alkaline batteries. Refer to the instructions listed in the Setup and Calibration
section of this manual for information on how to change these parameters.
1 = nControl Format 1

SETUP REVIEW

16
2 = nControl Format 2

Hide quick links:

Advertisement

Table of Contents
loading