DIGITAL FILL CONTROL ID STORAGE

If the setup parameter Stor=YES, then up to 25 DFC-ID filling settings can be saved.
To Add a DFC-ID Setting
1. With the indicator in normal operations mode, press the  key. The display will change
FUnCt=, press the PRESET key.
2. Enter up to a 6-digit alphanumeric ID string and press the ENTER key.
3. SINGLE SPEED:
The display will show FiLL
displayed weight is acceptable press the ENTER key, otherwise, use the numeric keys to
enter the new Fill weight and press ENTER.
TWO SPEED:
The display will show FASt
displayed, if the displayed weight is acceptable press the ENTER key, otherwise, use the
numeric keys to enter the new FASt weight and press ENTER.
4. SINGLE SPEED:
Skip to step 5.
TWO SPEED:
The display will change to SLo=, press the ENTER key. A zero SLO weight will be
displayed, if the displayed weight is acceptable press the ENTER key, otherwise, use the
numeric keys to enter the new SLO weight and press ENTER.
NOTE: The SLO weight MUST be greater than the FASt weight.
5. The display will change to show trin=, press the ENTER key and the current trim weight
will be displayed. If this value is acceptable press the ENTER key, otherwise, use the
numeric keys to enter a new trim weight and press the ENTER key.
6. The display will change to ACCU=, press the ENTER key to show a zero value for the
accumulator associated with this ID.
7. If a zero value is correct, press the ENTER key to save it. Otherwise, using the numeric
keys enter the accumulator value and then press the ENTER key to save it.
8. The display will change to CoUnt=, press the ENTER key to show a zero value for the
number of batches associated with this ID.
9. If a zero value is correct, press the ENTER key to save it. Otherwise, using the numeric
keys enter the number of batches and then press the ENTER key to save it.
10. The indicator will return to normal operation.
8200-M585-O1 Rev D  210 Installation & Technical
=
, press the ENTER key. A 0 Fill weight will be displayed, if the
=
, press the ENTER key. A zero FASt weight will be