Unpack the unit
1.
Follow applicable step:
- If the unit is packed in a carton, then remove
the staples and open the carton.
- If the unit is packed in a wooden crate, then
open the cover while paying attention to the
nails and straps.
2.
Remove the securing screws or the straps from
the wooden base.
2.1.1
Inspect the unit
1.
Remove packing materials from the product.
Dispose of all packing materials in accordance
with local regulations.
2.
Inspect the product to determine if any parts
have been damaged or are missing.
3.
If applicable, unfasten the product by removing
any screws, bolts, or straps.
For your personal safety, be careful when you
handle nails and straps.
4.
Contact the local sales representative if there is
any issue.
2.2 Transportation guidelines
Precautions
WARNING:
Observe
prevention regulations in
force.
Crush hazard. The unit
and the components can
be
lifting methods and wear
steel-toed shoes
times.
Check the gross weight that is indicated on the
package in order to select proper lifting equipment.
Position and fastening
The pump or pump unit can be transported only
horizontally. Make sure that the pump or pump unit
is securely fastened during transportation and
cannot roll or fall over.
WARNING:
Do not use eyebolts screwed on the
motor for handling the whole electric
pump unit.
Do not use the shaft end of the pump
or of the motor to handle the pump,
the motor or the unit.
Eyebolts screwed onto the motor may be
exclusively used to handle the individual
motor or, in case of a not balanced
distribution of weights, to partially lift the
18
accident
heavy.
Use
proper
at all
unit vertically starting from a horizontal
displacement.
Pump unit must always be fixed and transported as
shown in Figure 6 on page 94, and the pump without
motor must be fixed and transported as shown in
Figure 7 on page 94.
In this last case remove coupling guards from drive
lantern and cross the lifting ropes/bands.
2.3 Storage guidelines
Storage location
The product must be stored in a covered and dry
location free from heat, dirt, and vibrations.
NOTICE:
Protect the product against humidity, heat
sources, and mechanical damage.
NOTICE:
Do not place heavy weights on the packed
product.
2.3.1
Long-term storage
If the unit is stored for more than 6 months, these
requirements apply:
Store in a covered and dry location.
Store the unit free from heat, dirt, and
vibrations.
Rotate the shaft by hand several times at
least every three months.
For questions about possible long-term storage
treatment services, please contact Xylem or the
Authorised Distributor.
Ambient temperature
The product must be stored at an ambient
temperature from -5°C to +40°C (23°F to 104°F).
3
Product Description
3.1 Pump design
The pump is a horizontal pump with volute casing
close coupled to ATEX electric motors.
The pump can be used for handling:
Cold or warm liquid
Liquids which are moderately aggressive
to the pump materials.
Intended use
The pump is suitable for:
Use in environments with potentially
explosive atmospheres, due to presents
of flammable substances in the form of
gas, vapor, or mist.
Incorrect use