6.
References
to
standards used or references to the other
technical specifications, in relation to which
conformity is declared:
refer
to
electric
declaration of conformity included in the supply.
7.
Notified body: -
8.
Additional information: -
Signed for and on behalf of:
Xylem Service Italia S.r.l.
Montecchio Maggiore, 11.03.2016
Amedeo Valente
(Director of Engineering and
R&D)
rev.01
1.6.3
EU Declaration of Conformity (No
ATEX03)
1.
Product model:
see label on first page
2.
Name and address of the manufacturer:
Xylem Service Italia S.r.l.
Via Vittorio Lombardi 14
36075 Montecchio Maggiore VI
Italy
3.
This declaration of conformity is issued under
the sole responsibility of the manufacturer.
4.
Object of the declaration:
electric pump, composed of
Pump
II 2G c IIC T4 T
-10 +55°C
amb
Electric motor, in one of following versions
II 2G Ex d IIC T4 Gb IP55 T
II 2G Ex d IIC T4 Gb IP65 T
II 2G Ex d IIC T4 Gb IP55 T
II 2G Ex d IIC T4 Gb IP65 T
II 2G Ex d IIB T4 Gb IP55 T
II 2G Ex d IIB T4 Gb IP65 T
II 2G Ex d IIB T4 Gb IP55 T
II 2G Ex d IIB T4 Gb IP65 T
II 2G Ex de IIC T4 Gb IP55 T
II 2G Ex de IIC T4 Gb IP65 T
II 2G Ex de IIC T4 Gb IP55 T
II 2G Ex de IIC T4 Gb IP65 T
II 2G Ex de IIB T4 Gb IP55 T
II 2G Ex de IIB T4 Gb IP65 T
II 2G Ex de IIB T4 Gb IP55 T
II 2G Ex de IIB T4 Gb IP65 T
the
relevant
harmonised
motor
manufacturer's
-10 +55°C
amb
-10 +55°C
amb
0 +40°C
amb
0 +40°C
amb
-10 +55°C
amb
-10 +55°C
amb
0 +40°C
amb
0 +40°C
amb
-10 +55°C
amb
-10 +55°C
amb
0 +40°C
amb
0 +40°C
amb
-10 +55°C
amb
-10 +55°C
amb
0 +40°C
amb
0 +40°C
amb
II 2G Ex nA IIC T3 Gc IP55 T
II 2G Ex nA IIC T3 Gc IP65 T
II 2G Ex nA IIB T3 Gc IP55 T
II 2G Ex nA IIB T3 Gc IP65 T
5.
The object of the declaration that is described
above is in conformity with the relevant Union
harmonization legislation related to equipment
that is intended for use in potentially explosive
atmospheres:
– Directive 2014/34/EU of 26 February 2014
6.
References
to
standards used or references to the other
technical specifications, in relation to which
conformity is declared:
Pump
EN 1127–1:2011, EN 15198:2007, EN
13463–1:2009, EN 13463–5:2011
Electric
Electric
motor
declaration of conformity included in
the supply.
7.
The notified body:
Pump
SGS Baseefa Limited (NB 1180)
performed the EU-type examination
and
issued
Baseefa16ATEX0067X
Electric
Electric
motor
declaration of conformity included in
the supply.
8.
Additional information: the following specific
conditions of use apply.
- The equipment must be suitably earthed prior
to operation.
- It is the user's responsibility to ensure the
equipment does not run dry. Any control
system used to achieve this must comply with
the relevant requirements of EN 13463–6.
- For T4 operation the maximum temperature
of the process fluid must not exceed +90°C.
Signed for and on behalf of:
Xylem Service Italia S.r.l.
Montecchio Maggiore, 11.03.2016
Amedeo Valente
(Director of Engineering and R&D)
rev.00
Lowara is a trademark of Xylem Inc. or one of its
subsidiaries.
2

Transportation and Storage

2.1 Inspect the delivery
1.
Check the outside of the package for evident
signs of damage.
2.
Notify our distributor within eight days of the
delivery date, if the product bears visible signs
of damage.
en - Original instructions
0 +40°C
amb
0 +40°C
amb
0 +40°C
amb
0 +40°C
amb
the
relevant
harmonized
motor
manufacturer's
the
certificate:
motor
manufacturer's
17

Advertisement

loading