Mechanical Stress Test Results - Basler DART BCON SERIES User Manual

Table of Contents

Advertisement

AW00136902000
3.4.3

Mechanical Stress Test Results

The following mechanical stress tests were performed on the Basler dart cameras:
dart bare board cameras: See the stress tests for the dart S-mount camera. Because the
circuit board of bare board models is the same as the circuit board of S-mount and CS-mount
models, individual stress tests are not carried out for bare board cameras.
dart S-mount and CS-mount cameras: The cameras were subjected to the stress tests listed
in
Table
5. After mechanical testing, the cameras exhibited no detectable physical damage and
produced normal images during standard operational testing.
Test
Vibration
(sinusoidal, each axis)
Shock (each axis)
Bump (each axis)
Vibration
(broad-band random,
digital control, each axis)
Table 5: Mechanical Stress Tests for dart S-mount Cameras
The mechanical stress tests for S-mount cameras were performed with a dummy lens
attached. The dummy lens had a mass of 30 g.
The mechanical stress tests for CS-mount cameras were performed with a dummy lens
attached. The dummy lens had a mass of 66 g.
Using a heavier lens requires an additional support for the lens.
Basler dart BCON
Standard
Conditions
DIN EN 60068-2-6
10-58 Hz / 1.5 mm_58-500 Hz / 20 g_1 Octave/Minute
10 repetitions
DIN EN 60068-2-27
20 g / 11 ms / 10 shocks positive
20 g / 11 ms / 10 shocks negative
DIN EN 60068-2-27
20 g / 11 ms / 100 shocks positive
20 g / 11 ms / 100 shocks negative
DIN EN 60068-2-64
15-500 Hz / 0.05 PSD (ESS standard profile) / 00:30 h
Technical Specifications and Requirements
19

Advertisement

Table of Contents
loading