AW00118508000
1.8

Mechanical Stress Test Results

racer cameras were submitted to an independent mechanical testing laboratory and subjected to
the stress tests listed below. The mechanical stress tests were performed on selected camera
models with standard housing. After mechanical testing, the cameras exhibited no detectable
physical damage and produced normal images during standard operational testing.
Test
Vibration
(sinusoidal, each axis)
Shock (each axis)
Vibration
(broad-band random,
digital control, each axis)
Table 5: Mechanical Stress Tests
Basler racer Camera Link
Standard
Conditions
DIN EN 60068-2-6
10-58 Hz / 1.5 mm_58-500 Hz / 20 g_1 Octave/Minute
10 repetitions
DIN EN 60068-2-27
20 g / 11 ms / 100 shocks positive
20 g / 11 ms / 100 shocks negative
DIN EN 60068-2-64
15-500 Hz / 0.05 PSD (ESS standard profile) / 00:30 h