AW00136902000
5.2.6
Sync Pattern
Whenever the frame valid bit (FVal) is low and the camera is not sending frame information or line
checksum data, a fixed sync pattern is transmitted. This allows you to set up the correct word
alignment.
WordClk
MSB
X0
X1
X2
X3
Fig. 22: BCON Sync Pattern
5.2.7
BCON Output Bits
The BCON interface provides two bits that can be used to transmit two camera output signals:
Output 0 and Output 1.
Output 0 and Output 1 are transmitted on data lane X0 at position 0 and 1 (see Figure 21 on
page
33).
Depending on the camera model, the following output signals can be available:
Flash Window
Exposure Active
User Output 1
User Output 2
For more information about configuring output signals, see Section 8.2 on
Basler dart BCON
Clock cycle
BCON Interface
LSB
page
53.
37