Machine Model Adjustments And Speeds - Ce Only - JLG T500J Service And Maintenance Manual

Table of Contents

Advertisement

FUNCTION
DRIVE
FORWARD (25' COURSE)
REVERSE (25' COURSE)
ACCEL
DECEL
L FWD MIN
L FWD MAX
L REV MIN
L REV MAX
R FWD MIN
R FWD MAX
R REV MIN
R REV MAX
LIFT
ACCEL
DECEL
MIN UP
MAX UP
MIN DOWN
MAX DOWN
CREEP
SWING
ACCEL
DECEL
MIN LEFT
MAX LEFT
MIN RIGHT
MAX RIGHT
CREEP
TELESCOPE
ACCEL
DECEL
MIN IN
MAX IN
MIN OUT
MAX OUT
CREEP
3121200
Table 6-4. Machine Model Adjustments and Speeds - CE Only
1,4
ADJUSTMENT
5
Electric
RANGES
0.1 to 5.0 sec
1.0
0.1 to 3.0 sec
0.5
0 to 100%
15
0 to 100%
50
0 to 100%
15
0 to 100%
50
0 to 100%
15
0 to 100%
50
0 to 100%
15
0 to 100%
50
0.1 to 5.0 sec
2.5
0.1 to 3.0 sec
1.3
0 to 25% (75%)
3
0 to 100% (85%)
73
0 to 25% (50%)
14
0 to 35% (65%)
26
0 to 50%
50
0.1 to 5.0 sec
2.7
0.1 to 3.0 sec
1.0
0 to 25% (75%)
4
0 to 50% (85%)
35
0 to 25% (75%)
4
0 to 50% (85%)
35
0 to 35%
30
0.1 to 5.0 sec
1.5
0.1 to 3.0 sec
0.8
0 to 25% (75%)
1
0 to 100% (85%)
80
0 to 25% (75%)
10
0 to 100% (85%)
100
0 to 35%
30
MODEL DEFAULTS
Gas
1.0
0.5
15
50
15
50
15
50
15
50
2.5
1.3
56
66
25
46
50
2.7
1.0
58
63
50
63
30
1.5
0.8
57
72
60
80
30
SECTION 6 - JLG CONTROL SYSTEM
MODEL TIME RANGE (SECONDS)
Electric
Gas
20-28
19-22
20-28
19-22
40-50
40-50
43-53
43-53
65-105
65-105
65-105
65-105
19-26
19-26
19-26
19-26
2,3
6-23

Advertisement