FUNCTION
Note 1: Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
Note 2: Stop watch should be start when function starts. The exception is the drive function.The machine should have a running start.Stop watch as you cross the start line. 
The drive distance is 25 feet.
Note 3: Unless noted, function speeds should be measured from the platform with one operator.
Note 4: All test should be done with the oil temp above 65°F (15.5°C).
Note 5: Ranges shown in "( )" are exceptions for Gas-powered machines.
Note 3: With swing motor P/N 3160182 optimum performance is achieved with these settings: 
SWING, MAX (RT OR LT): Electric = 18%, gas = 61%, time = 85-105 seconds
With swing motor P/N 3160331 optimum performance is achieved with these settings:
SWING, MAX (RT OR LT): Electric = 34%, time=75-95; gas = 60%, time = 65-85 seconds
3121200
Table 6-4. Machine Model Adjustments and Speeds - CE Only
1,4
ADJUSTMENT
5
Electric
RANGES
MODEL DEFAULTS
Gas
SECTION 6 - JLG CONTROL SYSTEM
MODEL TIME RANGE (SECONDS)
Electric
Gas
2,3
4150561-H
6-25