SECTION 6 - JLG CONTROL SYSTEM
FUNCTION
PLATFORM LEVEL
ACCEL
DECEL
MIN UP
MAX UP
MIN DOWN
MAX DOWN
JIB LIFT
ACCEL
DECEL
MIN UP
MAX UP
MIN DOWN
MAX DOWN
OUTRIGGERS
ACCEL
DECEL
MIN SET
MAX SET
MIN STOW
MAX STOW
JOYSTICK
FWD IN
FWD MAX
REV IN
REV MAX
LEFT IN
LEFT MAX
RIGHT IN
RIGHT MAX
GROUND
ALARM
6-22
Table 6-3. Machine Model Adjustments and Speeds - ANSI & CSA
1,4
ADJUSTMENT
5
Electric
RANGES
0.1 to 5.0 sec
0.1
0.1 to 3.0 sec
0.1
0 to 25% (75%)
12
0 to 50% (85%)
27
0 to 25% (75%)
12
0 to 50% (85%)
27
0.1 to 5.0 sec
2.5
0.1 to 3.0 sec
0.8
0 to 25% (75%)
14
0 to 50% (85%)
26
0 to 25% (75%)
14
0 to 50% (85%)
28
0.1 to 5.0 sec
0.5
0.1 to 3.0 sec
0.5
0 to 25% (75%)
10
0 to 100% (85%)
100
0 to 25% (75%)
10
0 to 100% (85%)
100
0.50-4.50V
2.75
0.50-4.50V
4.35
0.50-4.50V
2.25
0.50-4.50V
0.65
0.50-4.50V
2.25
0.50-4.50V
0.65
0.50-4.50V
2.75
0.50-4.50V
4.35
87 to 107dB
87
MODEL DEFAULTS
Gas
0.1
0.1
53
72
53
72
2.5
0.8
50
62
15
46
0.5
0.5
65
85
65
85
2.75
4.35
2.25
0.65
2.25
0.65
2.75
4.35
107
2,3
MODEL TIME RANGE (SECONDS)
Electric
Gas
20-25
20-25
13-18
15-21
4150561-H
3121200