Emi Filter; Fuses - Maytag MXR65 Service Manual

Hide thumbs Also See for MXR65:
Table of Contents

Advertisement

eMi FilTeR

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Open the top panel. (See page 3-1)
2. The EMI or Electro-Magnetic Interference
filter is in left back corner, below the mains
disconnect, inside the cabinet.
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Remove two T-20 screws that secure the
guard over the fuses on the back panel.
2. To remove a fuse, use a flat blade
screwdriver to twist a fuse holder one
quarter turn to the left and pull it out.
NOTe: The top two fuses, numbers 1 and
2, are 1 amp, 250 volt. The 3rd and bottom
fuse is only on the MXR40-65 models that
EMI Filter
use an Isolating/Separating Transformer.
This fuse is .5 amp, 250 volt.
3. To access wire connectors for fuse sockets,
open the top panel. (See page 3-1)
4. Wire connectors for the fuse sockets are at
the back left corner of the washer cabinet.
3-31

FuSeS

Electrical Shock Hazard
Two T-20
Screws
Fuse Wire
Connectors

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxr40Mxr55Mxr30Mxr25PdMxr20 ... Show all

Table of Contents