Disassembly Procedures
!

Reactor Removal

1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove single attachment screw on cross brace.
4. Twist Reactor counterclockwise to remove.
©2005 Maytag Services
WARNING
16025909 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
NOTE: The reactor coil is wired in series with line 1
internally in the Control Board. An open coil or
loose electrical connection would result in a
"dead" board complaint. A resistance check
across the coil leads should indicate less than 1
ohm.

EMI Filter Removal

1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Loosen 13mm acorn nut and slide EMI Filter out of
bracket.
NOTE: Mark the wire locations on the EMI before
removing the terminals.