8. Remove the chemical dispenser outer
gasket by lifting up at the edge and peeling
the gasket away from the edge of the
dispenser. The cutouts on the back edge of
the gasket are for the lid hinges.
9. Remove two T-20 screws from the front
edge of the dispenser frame.
Two T-20
Screws
10. Lift the front edge of the dispenser and
slide it forward to release the two tabs at the
back edge of the dispenser and allow the
dispenser to be lifted.
11. Lift the dispenser out of the support.
12. Reinstall the gasket before reinstalling the
dispenser. Make sure the gasket is wrapped
under the edge of the frame, all the way
around the dispenser.
Gasket
Wrapped
3-21
Dispenser
Edge