auTOMaTiC DOOR ReleaSe MODule - PD MODelS
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Open the control panel. (See page 3-2)
2. Lean the control panel down, leaving it on
the lower hooks, to access the automatic
door release module.
3. Disconnect wire connectors from board.
Press thumb lock and pull connector off.
L1
L2
Brown
Grey
4. To remove the board from the control panel,
5. Pull the board away from the washer and
6. If replacing the chemical dispenser support,
T1
T6
T2 - Orange - To Door Lock #4 - Closed Switch
T9 - Brown - To Door Lock #8 - Closed Switch
T10 - Red - To Door Lock #7 - Locked Switch
T13 - Purple - To Door Lock #3 - Locked Switch
T16 - White - To Door Lock #6 - Solenoid Coil
3-7
squeeze the five standoffs, with needle
nose pliers, to release corners of the board.
remove it.
remove the five standoffs that secure the
automatic door release module. Reinstall
them in the new support.
Five
Standoffs
DT6
DT1
DT1 - Brown - To L1
DT4 - White - To DL16
DT5 - Black - To DL8
DT6 - Orange - To DL2
DT8 - Purple - To DL13
(L2 - 230VAC)