Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Remove the front plate. (See page 3-41)
2. Remove three T-20 screws that secure the
door lock behind door support front plate.
(See page 3-40)
3. Remove fifteen 10mm nuts that secure door
support front plate to the tub front cover.
10mm Nuts
DOOR SuPPORT FRONT PlaTe
4. Use a pry bar behind the door support front
plate, around the tub opening, to remove it
from the tub front cover.
NOTe: There are hinge plates riveted on
the inside.
3-44
Hinge