Inspect Counter-weight Cables-Annually
Henny Penny 8 head fryers use two cables in the counter-weight
mechanism that helps in the raising and lowering of the lid. Cables
should be visually inspected yearly, either as part of a planned
maintenance program or during a routine service call. Cables more than
10 years old should be replaced regardless of inspection results.
If lid becomes difficult to operate, stop using the
fryer and call for service. Cables need replaced.
1.
Using a 3/8" socket, remove the 6 keps nuts around exterior of rear
cover, shown in Figure 1.
2.
Lift up on the rear cover and pull out at the bottom to clear threaded
studs. Figure 2. (Removing top shroud makes it easier to remove the
rear cover, but is not necessary.)