3-1.
OPERATING COMPONENTS
(CONT.)
Safety Relief Valve Ring
Pressure Gauge
Solenoid Valve
Drain Valve
Oct. 2016
An ASME approved spring loaded valve set at 14.5 psi (999 mbar);
in the event the operation valve becomes obstructed, this safety valve
releases excess pressure, keeping the frypot chamber at 14.5 psi
(999 mbar); if this occurs, turn the COOK/ PUMP switch to the OFF
position to release all pressure from the frypot
If safety relief valve activates, turn main power
switch to the OFF position. To avoid serious burns
and injuries, have fryer serviced before next use.
DO NOT PULL THIS RING. SEVERE
BURNS FROM THE STEAM WILL RESULT.
DO NOT USE THE TEST LEVER OR
RING AS A LIFTING DEVICE FOR
Indicates the pressure inside the frypot.
An electromechanical device that causes pressure to be held in the
frypot
The solenoid valve closes at the beginning of the Cook Cycle and
opens automatically at the end of the Cook Cycle; if this valve
becomes dirty or the teflon seat nicked, pressure will not build and it
must be repaired per the Maintenance Section of the Technical Manual
A two-way ball valve, normally in the closed position; turn the handle
to drain the shortening from the frypot into the filter drain pan
DO NOT OPEN THE DRAIN VALVE WHILE
FRYPOT IS UNDER PRESSURE. HOT
SHORTENING WILL EXHAUST, AND
SEVERE BURNS WILL RESULT.