2-2.
UNPACKING
INSTRUCTIONS
(CONT.)
CAP
DEAD
WEIGHT
SHIPPING
SUPPORT
(DISCARD)
HOUSING
Dec. 2016
7.
Remove the counterweights from the pallet, which are strapped to
the pallet, under the fryer.
Do not drop. The counterweights weigh
approximately 18 lbs. (8.1 kg.) each. Handle
with care, or personal injury could result.
8.
Remove rear service cover.
9.
Load the seven weights into the counterweight assembly. See
page 2-4.
10.
Replace rear service cover.
To avoid personal injury and assure
safe operation of unit, rear service
11.
Cut warning tags from the lid assembly. The lid may now be
unlatched.
12.
Remove the accessories from inside the filter drain pan.
13.
Prepare the deadweight valve for operation
The metal shipping support is placed within the
deadweight assembly housing to protect the deadweight
orifice and deadweight during shipment. This support
must be removed prior to installation and start-up.
A.
Unscrew the deadweight cap.
B.
Remove the deadweight.
C.
Remove and discard the metal packing support.
D.
Clean the deadweight orifice with a dry cloth.
E.
Carefully place deadweight over deadweight orifice. Replace
deadweight cap, finger tight.
13.
Remove the protective paper from the fryer cabinet. Clean exterior
surface with a damp cloth.
6
cover must be in place.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfe-590

Table of Contents