Reference
Parameter group
6.4.4
Advanced Setup
6.4.5
Temperature Setup
6.4.6
Jog Control Setup
66 Basic operation – Pro models
Parameters
Factory Default (where applicable)
Kickstart Voltage % = 60%
•
•
Kickstart Period = 0.2s
Constant Current % = 50%
•
Pedestal RampUp % = 20%
•
•
Pedestal RampDown % = 50%
MSC % = 200%
•
MULC % = 80%
•
•
MOLC % = 100%
Maximum Starts/Hour = 10
•
•
Ramp Start Angle % = 0%
•
Alpha Skip Start % = 36%
Alpha Skip Stop % = 36%
•
Note that same value for Skip Start and Stop
implies that the Skip is disabled.
Heatsink Fan Control = No
•
Maximum Motor Temp = 120°C
•
•
Heatsink Restart Temp = 40°C
Motor Restart Temp = 45°C
•
Heatsink Fan Start = 40°C
•
•
Motor Temp Selection = PT100
Note: TMotor indicates that the LM35 sensor is
selected.
Jog Motor Voltage = 0
•
(Jog disabled)