15.5.3) Checking of the throttle position

Ill. 42
Date
Page
1996 05 10
60
See Ill. 42.
Start of the sub program MONITOR.
throttle position
Throttle position is displayed in the middle of the top line (carb 2/4)
0 %
115 %
visually check whether the throttle on both carburetors can be fully
opened and closed. If necessary correct the installation setting
check of the display with throttle completely closed:
°
nominal: 0
check of the display with throttle fully open:
nominal: 115 % tolerance -2%
ATTENTION: Check whether indication is linear over the complete range
from 0% to 115% i.e. the 115% position is not indicated
before throttle is fully open.
Check of the display at max. continuous power.
ATTENTION: Throttle lever must be in positive stop position
nominal: 100 % tolerance +3%.
WARNING: This check of position is only meaningful and allowed, if idle-
and full throttle position are within the allowance variation.
If the throttle position for idle and full throttle are not within the allowance
variation or if not proceeding linear, then a new calibration of the throttle
position is absolutely necessary. Refer to Maintenance Manual 914 F.
Install
914 F
throttle completely closed
throttle fully open
tolerance +3%
Reference
Modification-No.
- 0 -