(A)
20
10

17.3.3) Electronic modules

17.3.4) Ignition switches (MAG switch)

Effectivity: 912 Series
Edition 1 / Rev. 0
INSTALLATION MANUAL
During engine stop break circuit between battery and
terminal C to avoid discharge of battery! (see Fig. 67)
◆ NOTE:
A charge-indicating lamp 3W/12V (Fig. 67, pos. (18)
may be fitted on the instrument panel.
Current:
■ CAUTION:
The graph current over engine speed has been deter-
mined and is valid only at the following conditions.
ambient temperature: ....... 20 °C (68 °F)
voltage: ............................ permanent 13,5 V
tolerance: ......................... max ± 5%
0
1000
2000
3000
4000
See Fig. 4 and 71.
Ambient temp. for the electronic modules (1): max. 80 °C (176 °F).
See Fig. 71, 72 and 73.
-
type: two separate, suitable on-off
switches (Fig. 67, pos. (15))
-
switching voltage: min. 250 V
-
switching current: min. 0,5 A
Wires from the ignition switches connect
to the electronic module (see Fig. 71).
BRP-Rotax
(1/min.)
5000
6000
Fig. 70
02500
Fig. 71
02501
Cyl. 2
B
br
Cyl. 4
br
A
May 01/2007
Cyl. 1
Cyl. 3
1
page 112