EBP 100 and EBP 200 • Setup Guide
The Extron EBP 100 and EBP 200 eBUS
IPCP Pro Series Control Processors.
Each EBP button panel includes two eBUS ports, which support both power and communications between the IPCP Pro
control processor and eBUS devices. Up to eight eBUS endpoint devices such as EBP button panels can be connected to
the control processor and to each other in various cabling topologies. Cabling topology refers to the physical layout of cabling
interconnections between devices in a network such as an eBUS system. eBUS systems can include daisy chain, star, or hybrid
system (a combination of both types) topologies (see the EBP 100 and EBP 200 User Guide for basic diagrams). Every endpoint
device must have a unique identification address (bus ID) within the system.
Setup involves setting bus ID DIP switches on the EBPs, then using Extron Global Configurator
software, or Global Scripter programming, to configure the control processor. Once configured, the AV system can be controlled
from any of its EBPs.
This guide provides basic instructions for an experienced installer to install an EBP 100 or EBP 200 button panel. For more details
on the EBPs, see the EBP 100 and EBP 200 User Guide, available on www.extron.com. For details on configuration, see the
software help files.
Features
Front Panel Features
A A A
A
DISPLAY
C
C C C
ON
ON
OFF
OFF
VOLUME
VOLUME
D D D
D
Extron
Extron
EBP 100 Front Panel with Faceplate
A
A A A
DISPLAY
C C C
C
ON
OFF
VOLUME
VOLUME
D D D
D
EBP 200 Front Panel with Faceplate
Front Panels With and Without Faceplates
Figure 1.
Button Panels are fully customizable AV system control interfaces for use with Extron
®
PC
LAPTOP
LAP
E E E
E
VID
VIDEO
F F F
F
MU
MUTE
PC
LAPTOP
VGA
HDMI
E
E E E
DOC
SCREEN
CAM
UP
SCREEN
MUTE
DOWN
Extron
Extron
B
B B B
E
PC
RESET
EBP 100 Front Panel without Faceplate
E
ON
OFF
F
F F F
RESET
EBP 200 Front Panel without Faceplate
(GC) Plus and Professional
®
A
Faceplate
B
Mounting holes
(EBP 100: x4, EBP 200: x6)
C
Display power buttons
D
Volume LEDs and knob
E
Function buttons
F
Reset LED and button
B B B
B
PC
LAPTOP
VGA
HDMI
DOC
SCREEN
CAM
UP
SCREEN
MUTE
DOWN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBP 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Extron electronics EBP 100

  • Page 1 EBP 100 and EBP 200 • Setup Guide The Extron EBP 100 and EBP 200 eBUS Button Panels are fully customizable AV system control interfaces for use with Extron ® IPCP Pro Series Control Processors. Each EBP button panel includes two eBUS ports, which support both power and communications between the IPCP Pro control processor and eBUS devices.
  • Page 2: Rear Panel Features

    EBP 100/200 Series • Setup Guide (Continued) Rear Panel Features NOTE: For rear panel features, all models are identical. A A A Bus ID DIP switches B B B eBUS ports eBUS status LED C C C Maximum power load rating...
  • Page 3: Site Preparation

    Site preparation Model US Gang Size EBP 100 EBP 200 Extron offers an assortment of mud rings, optional UL Listed in-wall junction boxes, external wall boxes (EWBs), and surface or tabletop mounting boxes for use with the eBUS button panels.
  • Page 4 EBP 100/200 Series • Setup Guide (Continued) Step 4: Set Bus ID Addresses Set the bus identification DIP switches for each EBP button panel in the system using the diagrams in this section as a guide. Each eBUS endpoint device, such as an EBP, must have a unique bus ID (address). If other modules have the same bus ID, address conflicts may cause one or more of the panels to not be recognized by the IPCP Pro control processor.
  • Page 5 Cabling Attach cables using the diagrams in this section as a guide. Wiring is the same for all models. Connect a 4-pole captive screw connector to each end of the cable, wiring both ends the same. In most cases the EBPs are powered by the IPCP Pro control processor that provides the eBUS signal.
  • Page 6: Step 6: Configure The System

    EBP 100/200 Series • Setup Guide (Continued) Power Input, External Power Supply (optional) • Connect to an Extron 12 VDC, 1 A, power supply. 3/16" (5 mm) Max. eBUS port on an IPCP Pro control processor Tie drain wires to ground.
  • Page 7 Using a Phillips screwdriver, lightly Wall tighten the screws until snug. Wall Plastic Spacer D I S EBP 100 t r o Installing the EBP Figure 7. Faceplate in a Junction Box Wall Mounting...
  • Page 8 (Inside India Only) Extron USA - West Extron USA - East +31.33.453.4040 +91.80.3055.3777 +1.714.491.1500 +1.919.850.1000 +31.33.453.4050 FAX +91.80.3055.3737 FAX +1.714.491.1517 FAX +1.919.850.1001 FAX © 2016 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com...