Eaton 9390 Installation And Operation Manual page 69

40–80 kva ups, integrated distribution cabinet
Hide thumbs Also See for 9390:
Table of Contents

Advertisement

Table E
Basic Unit Rating
IDC Input and IDC Bypass Input
IDC Output
AC Input from UPS
(Standalone Installation)
(3) Phases, (1) Neutral---if required, (1) Ground
Minimum Conductor Size
Number per Phase
AC Input to Maintenance Bypass
(Standalone Installation)
(3) Phases, (1) Neutral---if required, (1) Ground
Minimum Conductor Size
Number per Phase
AC Input to Optional BIB
(Standalone Installation)
(3) Phases, (1) Neutral---if required, (1) Ground
Minimum Conductor Size
Number per Phase
AC Input from Optional BIB to UPS
(Standalone Installation)
(3) Phases, (1) Neutral---if required, (1) Ground
Minimum Conductor Size
Number per Phase
AC Input from Optional RIB to UPS
(Standalone Installation)
(3) Phases, (1) Neutral---if required, (1) Ground
Minimum Conductor Size
Number per Phase
AC Output from 225A Distribution Breaker
to Critical Load
(3) Phases, (1) Neutral, (1) Ground
AC Output from Output Terminal Block
to Critical Load
(3) Phases, (1) Neutral, (1) Ground
AC Output from Distribution Panel Breakers
to Critical Load
A, B, C, D, E
NOTE: Callout letters
INPUT/OUTPUT Ratings & External Wiring Requirements for
.
Eaton 9390 80 kVA IDC
A
B
C
D
E
F
F
F
F
and
Eaton 9390 IDC (40–80 kVA) Installation and Operation Manual 164201690 Rev Rev 3 www.eaton.com/powerquality
Units
UPS kVA
40/50/60/80
VOLTS
VOLTS
AMPS
111/139/167/222
For customer-supplied wiring, refer to the Eaton
9390 UPS (40–80 kVA) Installation and
AWG or kcmil
Operation Manual for wire size. Wiring for
(each)
line-up-and-match cabinet installation is
factory-supplied.
AMPS
111/139/167/222
AWG or kcmil
(each)
AMPS
125/155/185/240
AWG or kcmil
(each)
AMPS
125/155/185/240
For customer-supplied wiring, refer to the Eaton
9390 UPS (40–80 kVA) Installation and
AWG or kcmil
Operation Manual for wire size. Wiring for
(each)
line-up-and-match cabinet installation is
factory-supplied.
AMPS
125/155/185/240
For customer-supplied wiring, refer to the Eaton
9390 UPS (40–80 kVA) Installation and
AWG or kcmil
Operation Manual for wire size. Wiring for
(each)
line-up-and-match cabinet installation is
factory-supplied.
Wire branch circuits accordin g to the branch circuit breaker
manufacturer's ratings, and national and local electrical codes.
Wire output according to national and local electrical codes.
Refer to the Eaton 9390 UPS (40–80 kVA) Installation and Operation
Manual for output current rating and wire size.
Wire branch circuits accordin g to the branch circuit breaker
manufacturer's ratings and instr uctions, and national and local
electrical codes (output is prewired to the panelboard).
map to drawing 164201690 ---3.
DESCRIPTION:
POWER WIRING INSTALLATION NOTES
D
R
A
W
N I
G
N
: O
164201690---5
REVISION:
B
Rating 60 Hz
40/50/60/80
208
480
208
208
48/60/72/96
48/60/72/96
2/0
1/0
(2)
(1)
55/67/80/105
2/0
1/0
(2)
(1)
55/67/80/105
55/67/80/105
S
H
E
E
: T
DATE:
082707
2 of 7
9-13

Advertisement

Table of Contents
loading

Table of Contents