Eaton 9390 Brochure & Specs

20-160 kva

Advertisement

PowerChain Management solutions
20-160 kVA
Eaton 9390 UPS

Advertisement

Table of Contents
loading

Summary of Contents for Eaton 9390

  • Page 1 PowerChain Management solutions 20-160 kVA Eaton 9390 UPS...
  • Page 2 Eaton 9390 20-160 KVA EATON CORPORATION Product Catalog...
  • Page 3 Whether you’re selecting a UPS for a branch office, manufactur- ing floor, medical facility, or data center, there’s a 9390 model that delivers just the right combination of performance and price for your needs.
  • Page 4 90% efficient UPS delivers 90 kW of useful power for every 100 kW taken in. With a transformerless design and sophisticated sensing and control circuitry, the 9390 delivers an efficiency of up to 94 percent with double-conversion protection. In addition to the cost savings, this enhanced efficiency extends battery runtimes and produces cooler UPS operating temperatures, extending compo- nent life and increasing reliability and performance.
  • Page 5 THD THD enhances at less than 4.5% at full load— without compromising efficien- generator compatibility cy. As a result, the 9390 trans- Electronic devices and UPSs are fers maximum power between built with some components the source and protected load that are non-linear.
  • Page 6 Scalable architecture meets your current and future load requirements The 9390 supports up to 160 kVA to deliver power protection for small branch offices to large corporate data centers and communication networks. Up to six equivalent 9390 modules can be paralleled for additional capacity or redundancy, without having to utilize a central bypass cabinet.
  • Page 7 Eaton is there with you—able to respond to alarms and see real- time battery data to avert poten- tial battery problems. A TS Auto 9390 UPS Static Auto Tie Controls STATIC AUTO TIE Dual Power Cord Loads Single P ower Cord L oads...
  • Page 8 The 9390 offers the smallest footprint of any UPS in its class—35 to 50 percent smaller than competitive units. Cabling can enter the UPS from either the top or bottom of the cabinet to provide easier and flexible installation.
  • Page 9 Service provides confidence Additionally, the report provides that Eaton is continually watch- information about the attached ing your 9390 and will combine batteries and system availability. its technical resources and field All of these factors contribute to technicians as needed to quickly the Relative Health Index (RHI) respond to critical alarms.
  • Page 10: Power Conditioner

    Specialized applications The 9390 isn’t just an industry-leading UPS – it also serves in spe- cialized capacities across the globe. With its lightweight design and minimal footprint, it is used in a variety of applications where mobil- ity is a requirement.
  • Page 11: Battery Cabinet

    • Modular, removable battery Eaton offers two versions of bat- tray design and quick tery cabinets which line-up and disconnects between tray match the 9390; the IBC-S and assemblies optimizes periodic the IBC-L, each offering a wide maintenance array of runtimes. See powerware.com/9390 for...
  • Page 12 UPS to serve and strong customer service data center loads. K-rated commitments. transformers are available to support loads with high harmonic content. * See the Limited Factory Warranty for 9390 products for details. ® ® , PowerVision , and ® software. This...
  • Page 13 Typical application of 9390 Integrated Distribution Cabinet distributing power to IT racks. 480V input and 208/120V output with BIB. www.eaton.com/powerquality 1.800.356.5794...
  • Page 14 Integrated Accessory and rectifier input breaker (RIB) Cabinets (IAC) for use with the provide a single wiring point 9390 UPS. Major functions of input to the UPS as well as a the IAC include: maintenance convenient method for removing...
  • Page 15 Two UPS parallel configuration with 8-inch sidecar tie cabinet 42-pole panelboard Main Breaker (225A) for 42-pole panelboard Distribution breakers electronic adjustable with 250A sensors 100-250A with 100A sensors 40-100A IAC-D Distribution Cabinet Neutral connections Distribution breakers IAC-D (with dead front removed) www.eaton.com/powerquality 1.800.356.5794...
  • Page 16: Power Distribution Unit (Pdu)

    EATON CORPORATION Eaton 9390 Uninterruptible Power System 300 kVA PDU with optional sidecar and Energy Management System (EMS) A 24-month history log provides a powerful aid in capacity...
  • Page 17 A closer look inside the 9390 ® X-Slot communication bays System control and interface boards Modular static switch assembly X-Slot communication bays Redundant power supplies Modular static switch assembly Top cable entry area Replaceable convert- er/inverter modules Redundant power supplies...
  • Page 18 • Green technology – eliminates lead use in facility (batteries), As an alternative to conventional reduces energy consumption batteries, the 9390 is flywheel compatible. (A flywheel stores • Longer useful life (20 years kinetic energy well suited for versus average of five years...
  • Page 19 Up to 420 lbs 100-160 kVA (H”xW”xD”) 22.5 x 31.6 x 73.7 100-160 kVA (weight) Up to 420 lbs IDC technical specifications 9390 Integrated Distribution Cabinet General characteristics Installation Line up and match to UPS Front access only Color Same as UPS...
  • Page 20: Technical Specifications

    Expansion Option Remote panel - eight backlit status indicator lamps plus an audible horn *See the Limited Factory Warranty for 9390 products for details. Batteries are warranted by the battery manufacturer and not by Eaton. **Requires the Parallel Card option (RS-485 port) and requires an external 120V power supply to drive the remote monitor panel.