2. Input module type CP−E16−KL−IP20−Z

2.3.3 Connecting the sensors

Sockets in the connector set
type SEA−KL−SAC10/30
Tension spring socket, 1−row
Tension spring socket, 3−rows
Festo P.BE−CPEA−EN en 0802e
Caution
Long signal cables reduce the immunity to interference.
Do not exceed the maximum permitted signal cable length
of 30 m.
Caution
Make sure that pin 3 of the sensor supply connection is
bridged in accordance with the operating mode of your
system (PNP or NPN operation, see section 1.3.1).
Recommendation: Use the connector sockets from connecter
set type SEA−KL−SAC10/30.
Number
1
2
Two rows of the three−row connector socket are intended as
distributor boards for the sensor supply. These rows are each
connected internally (see Fig. 2/9).
Fasten these sockets with the aid of the fitted screws. The
S
maximum tightening torque is 0.2 Nm.
Recommended
Connection
for connection
cross−sec
tional area
See leaflet
X1
with product
See leaflet
X2, X3
with product
2−13