2
Function
2.1.3

Control elements

The address space (inputs/outputs) provided by the module is set using DIL switches è Tab. 2.1.
Switch position combinations that are not listed lead to an error (error number 204).
DIL switch
1) Factory setting
2) Only Port 1 [X0] and Port 2 [X1] active
3) Only Port 1 [X0] active
Tab. 2.1
2.1.4

Connecting components

Port [X0] ... [X3]
Tab. 2.2
1)
Connection [XD]
1) The connections XD.0 and XD.1 and also XD.2 and XD.3 are interconnected in the terminal strip.
Tab. 2.3
Festo – CPX-E-4IOL-...-EN – 2017-07 – English
1
2
3
4
OFF
Off
Off
Off
ON
Off
Off
Off
OFF
ON
Off
Off
ON
ON
OFF
ON
OFF
Off
ON
OFF
Signal
Description
0/1
C/Q
Standard IO (in SIO mode) or IO-Link communication
(in IOL mode)
2
L+
+24 V DC operating voltage supply U
3
P24
+24 V DC load voltage supply U
4
L–
0 V DC operating voltage supply U
5
N24
0 V DC load voltage supply U
Signal
0
+24 V DC load voltage supply U
1
2
0 V DC load voltage supply U
3
5
6 ... 8
Address space [byte]
Per port
1)
Off
OFF
2 I/2 O
Off
OFF
4 I/4 O
Off
OFF
8 I/8 O
2)
Off
OFF
16 I/16 O
3)
ON
OFF
32 I/32 O
EL/SEN
OUT
EL/SEN
OUT
OUT
OUT
Module
1)
8 I/8 O
16 I/16 O
32 I/32 O
7