Connecting Sensors - Festo CP-E08-M12-CL Manual

Cp modules
Hide thumbs Also See for CP-E08-M12-CL:
Table of Contents

Advertisement

2. Input modules type CP−E08−M...−CL and CP−E16−KL−CL

2.3.1 Connecting sensors

Festo P.BE−CPEA−CL−EN en 0404NH
Caution
Long signal cables reduce the immunity to interference.
Make sure that the maximum permitted signal cable length
of 30 m is not exceeded.
Use plugs and cables from the Festo range (see Appendix
A.5) for connecting sensors.
In the case of CP input modules type CP−E08−M12−CL and
CP−E08−M8−CL:
Fasten the plugs with the aid of the union nut in order to
·
prevent unintentional loosening, e.g. due to shock.
Seal unused connections with protective caps. Only in this
·
way can you comply with protection class IP65/IP67. Use
protective caps from the Festo range (see Appendix A.5).
With CP input module type CP−E16−KL−CL:
Further information on connector sets as well as instructions
on handling them can be found in Appendix A.5.4.