Technical Specifications; Homologations; Directives; Technical Data - DeDietrich GSHP 5 MR-E User Manual

Geothermal heat pump
Hide thumbs Also See for GSHP 5 MR-E:
Table of Contents

Advertisement

3 Technical specifications

3
Technical specifications
3.1

Homologations

3.2

Technical data

Tab.3
Pressure limitations
Maximum operating pressure of the heating circuit
Maximum operating pressure of the collector circuit
Tab.4
Temperature limitations
Limit operating temperatures on the heating circuit in Heating mode
Limit operating temperatures on the heating circuit in Cooling mode
Limit operating temperatures on the collection circuit (source)
Tab.5
Performances for a glycol water/water system (0°C/-3°C and 30°C/35°C), in accordance with NF EN 14511–1
Measurement
Unit
type
Power supply
V
(~50 Hz)
Coefficient of
performance
(COP)
Absorbed electri­
kW
cal power
Application flow
3
m
/h
rate
14
GSHP
3.1.1
This product complies with the requirements of the following European Di­
rectives and Standards:
Pressure Equipment Directive 97/23/EC, Article 3, paragraph 3
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standard: EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary
guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at
the time of installation shall apply to all regulations and guidelines speci­
fied in this manual.
3.2.1
3.2.2
GSHP 5
GSHP 5
GSHP 9
MR-E
TR-E
MR-E
230
400
230
single
three-
single
phase
phase
phase
4.38
4.38
4.39
1.30
1.30
2.25
0.98
0.98
1.70

Directives

Conditions of use

Heat pump

GSHP 9
GSHP
GSHP
TR-E
12 MR-E
12 TR-E
400
230
400
three-
single
three-
phase
phase
phase
4.39
4.35
4.35
2.25
2.91
2.91
1.70
2.18
2.18
0.3 MPa (3 bar)
0.3 MPa (3 bar)
+7°C / +80°C
+7°C / +25°C
-15 °C / +35 °C
GSHP
GSHP
GSHP
15 TR-E
19 TR
27 TR
400
400
400
three-
three-
three-
phase
phase
phase
4.50
4.28
4.10
3.80
4.76
6.83
2.95
3.52
4.83
7636860 - v04 - 18012017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents