Specific Safety Instructions; Refrigerant Fluid R410A - DeDietrich GSHP 5 MR-E User Manual

Geothermal heat pump
Hide thumbs Also See for GSHP 5 MR-E:
Table of Contents

Advertisement

1.3

Specific safety instructions

7636860 - v04 - 18012017
Caution
It is preferable to use HOLIDAYS mode rather
than switching off the heat pump to handle the
following functions:
Unblocking the circulating pumps,
frost protection.
Warning
Refrigerant fluid and pipes:
Use only R410A refrigerant fluid to fill the instal­
lation.
Use tools and pipe components especially de­
signed for use with R410A refrigerant fluid.
Use copper pipes deoxidised with phosphorus
to carry the refrigerant fluid.
Store the refrigerant connection pipes away
from dust and humidity (risk of damage to the
compressor).
Do not use a load cylinder.
Protect the heat pump components, including
the insulation and structural elements. Do not
overheat the pipes as brazed components may
cause damage.
Contact between the refrigerant fluid and a
flame may result in emissions of toxic gases.
1.3.1

Refrigerant fluid R410A

Hazard identification
Effects harmful to health:
The vapours are heavier than air and may lead to as­
phyxia owing to reduced oxygen levels.
Liquefied gas: contact with the liquid may cause seri­
ous frost burn and eye injuries.
Product classification: this product is not classified as
a "hazardous preparation" according to European Un­
ion regulations.
If the R410A refrigerant is mixed with air, it may cause
pressure surges in the refrigeration pipes and lead to an
explosion and other hazards.
Composition of / Information on the ingredients
Chemical nature: R-410A is composed of Difluorome­
thane R32 and Pentafluoroethane R125
1 Safety
GSHP
9