Parameters
SWIMMING P.T.B
SWIMMING P.T.C
WATER T.NIGHT
WATER T.NIGHT.A
WATER T.NIGHT.B
WATER T.NIGHT.C
WATER T.NIGHTAUX
Tab.15
Menu MODE
Parameters
FORCE AUTO
AUTOMATIC
DAY
NIGHT
HOLIDAYS
SUMMER
7636860 - v04 - 18012017
Description
Desired temperature for the swimming pool connected to cir
cuit B.
Can be set from 5 to 39°C.
Desired temperature for the swimming pool connected to cir
cuit C.
Can be set from 5 to 39°C.
Desired domestic hot water temperature in the domestic hot
water circuit.
Can be set from 10 to 75 °C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit A.
Can be set from 10 to 80°C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit B.
Can be set from 10 to 80°C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit C.
Can be set from 10 to 80°C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to the auxiliary circuit.
Can be set from 10 to 80°C.
Certain parameters are displayed:
Description
An operating mode override is activated on the remote con
trol (optional).
To force every circuit in AUTOMATIC mode, select the value:
ON.
The temperatures switch automatically from DAY mode to
NIGHT mode according to the setting on the #TIME
PROGRAM menu.
DAY mode is forced:
DAY -> : until the set time
DAY 7/7 : at all times 24/7
NIGHT mode is forced:
NIGHT -> : until the set time
NIGHT 7/7 : at all times 24/7
Frost protection mode is active:
DAYS ANTIFREEZ : number of days' holiday
STOP HEAT : heating shut-down date
RE-START : heating restart date
The start and end days and the number of days are calcula
ted in relation to each other.
SUMMER mode is forced:
the heating is shut down
domestic hot water continues to be produced
MODE menu - User Level
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Factory setting
Customer setting
20°C
20°C
10°C
10°C
10°C
10°C
10°C
Factory setting
Customer setting
Current time + 1
hour
Current time + 1
hour
Current date + 1
hour
GSHP
6 Settings
29