DeDietrich GSHP 5 MR-E User Manual page 29

Geothermal heat pump
Hide thumbs Also See for GSHP 5 MR-E:
Table of Contents

Advertisement

Parameters
SWIMMING P.T.B
SWIMMING P.T.C
WATER T.NIGHT
WATER T.NIGHT.A
WATER T.NIGHT.B
WATER T.NIGHT.C
WATER T.NIGHTAUX
Tab.15
Menu MODE
Parameters
FORCE AUTO
AUTOMATIC
DAY
NIGHT
HOLIDAYS
SUMMER
7636860 - v04 - 18012017
Description
Desired temperature for the swimming pool connected to cir­
cuit B.
Can be set from 5 to 39°C.
Desired temperature for the swimming pool connected to cir­
cuit C.
Can be set from 5 to 39°C.
Desired domestic hot water temperature in the domestic hot
water circuit.
Can be set from 10 to 75 °C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit A.
Can be set from 10 to 80°C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit B.
Can be set from 10 to 80°C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit C.
Can be set from 10 to 80°C.
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to the auxiliary circuit.
Can be set from 10 to 80°C.
Certain parameters are displayed:
Description
An operating mode override is activated on the remote con­
trol (optional).
To force every circuit in AUTOMATIC mode, select the value:
ON.
The temperatures switch automatically from DAY mode to
NIGHT mode according to the setting on the #TIME
PROGRAM menu.
DAY mode is forced:
DAY -> : until the set time
DAY 7/7 : at all times 24/7
NIGHT mode is forced:
NIGHT -> : until the set time
NIGHT 7/7 : at all times 24/7
Frost protection mode is active:
DAYS ANTIFREEZ : number of days' holiday
STOP HEAT : heating shut-down date
RE-START : heating restart date
The start and end days and the number of days are calcula­
ted in relation to each other.
SUMMER mode is forced:
the heating is shut down
domestic hot water continues to be produced
MODE menu - User Level
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Factory setting
Customer setting
20°C
20°C
10°C
10°C
10°C
10°C
10°C
Factory setting
Customer setting
Current time + 1
hour
Current time + 1
hour
Current date + 1
hour
GSHP
6 Settings
29