AWHP MIT-IN iSystem
6
Technical specifications
6.1
Technical specifications
AWHP
Calorific output -
kW
(1)
A7/W35
COP hot - A7/
(1)
W35
Absorbed
kWe
electrical power -
(1)
A7/W35
Nominal
A
amperage - A7/
(1)
W35
Calorific output -
kW
(2)
A2/W35
COP hot - A2/
(2)
W35
Absorbed
kWe
electrical power -
(2)
A2/W35
(1) Hot mode: Outside air temperature +7 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.
(2) Hot mode: Outside air temperature +2 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.
(3) Cooling mode: Outside air temperature +35 °C, Water temperature at the outlet +18 °C. Performances in line with EN 14511-2
(4) 5 m from the appliance, free field.
(5) Test conducted in accordance with the standard NF EN 12102
06/09/2012 - 300027618-001-01
6 MR
8 MR
11 MR 11 TR
6.0
8.5
10.9
4.00
4.10
4.23
1.5
2.1
2.6
6.8
9.2
11.2
4.4
5.9
7.6
3.12
3.12
3.10
1.4
1.9
2.5
6.1.1.
Electricity supply
230 V AC (+/- 10%) - 50 Hz
6.1.2.
Heat pump
Conditions of use:
4 Limit operating temperatures in Hot mode:
- Water: +18 °C / +55 °C
- Outside air:
-15 °C / +35 °C (AWHP 6 MR, 8 MR)
-20 °C / +35 °C (AWHP 11-27)
4 Limit operating temperatures in Cooling mode:
- Water: +7 °C / +25 °C
- Outside air: +15 °C / +40 °C (At less than 18°C, it is necessary
to use the HK24 insulation kit option)
4 Maximum operating pressure: 3 bar
14 MR 14 TR
10.9
13.7
13.7
4.23
4.03
4.03
2.6
3.4
3.4
6.7
14.8
8.8
7.6
10.3
10.3
3.10
3.10
3.10
2.5
3.3
3.3
6. Technical specifications
16 MR 16 TR
22 TR
15.7
15.7
19.4
3.90
3.90
3.94
4.03
4.03
4.9
17.6
10.1
12.3
10.4
10.4
11.6
3.10
3.10
3.11
3.4
3.4
3.9
27 TR
24.4
3.90
6.3
15.6
14.7
3.10
4.7
28