3 Technical specifications

3
Technical specifications
3.1

Homologations

3.2

Technical data

Tab.1
Conditions of use
Limit water operating
temperatures in heating
mode
Outdoor air operating
temperature limits in
heating mode
Water operating temper­
ature limits in cooling
mode
Outdoor air operating
temperature limits in
cooling mode
Tab.2
Heating mode: outside air temperature +7 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measurement type
Heat output
Coefficient of Perform­
ance (COP)
12
MIV-4S V200
3.1.1
This product complies with the requirements of the following European
Directives and Standards:
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary
guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at
the time of installation shall apply to all regulations and guidelines
specified in this manual.
3.2.1
The specifications are valid for a new appliance with clean heat
exchangers.
Maximum operating pressure: 0.3 MPa (3 bar)
AWHP 4.5
AWHP 6
MR
MR-3
+18 °C /
+18 °C /
+55 °C
+60 °C
-15 °C /
-15 °C /
+35 °C
+35 °C
+7 °C /
+7 °C /
+25 °C
+25 °C
+7 °C /
+7 °C /
+46 °C
+46 °C
Unit
AWHP 4.5
AWHP 6
MR
MR-3
kW
4.60
5.82
5.11
4.22

Directives

Pressure Equipment Directive 2014/68/EU
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standards: EN 60335-2-21, EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014

Heat pump

AWHP 8
AWHP 11
MR-2
MR-2
+18 °C /
+18 °C /
+60 °C
+60 °C
-20 °C /
-20 °C /
+35 °C
+35 °C
+7 °C /
+7 °C /
+25 °C
+25 °C
+7 °C /
+7 °C /
+46 °C
+46 °C
AWHP 8
AWHP 11
MR-2
MR-2
7.9
11.39
4.34
4.65
AWHP 11
AWHP 16
TR-2
MR-2
+18 °C /
+18 °C /
+60 °C
+60 °C
-20 °C /
-20 °C /
+35 °C
+35 °C
+7 °C /
+7 °C /
+25 °C
+25 °C
+7 °C /
+7 °C /
+46 °C
+46 °C
AWHP 11
AWHP 16
TR-2
MR-2
11.39
14.65
4.65
4.22
7682850 - v04 - 02082019
AWHP 16
TR-2
+18 °C /
+60 °C
-20 °C /
+35 °C
+7 °C /
+25 °C
+7 °C /
+46 °C
AWHP 16
TR-2
14.65
4.22